Malpositioning of Hickman Catheters, Left Versus Right Sided Attempts

Overview
Specialty Hematology
Date 2003 Mar 7
PMID 12620263
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Central venous catheters (CVC) are frequently used for stem cell collection and recurrent therapeutic hemapheresis procedures for patients with poor peripheral venous access. There is a tendency to prefer a right sided approach for insertion of a CVC via the subclavian route. We designed a sequential randomized study to examine the issue of catheter insertion side and analyzed all the technical data on surgical skill and observed complications.

Method: Seventy-five patients who are candidates for stem cell collection and high dose chemotherapy underwent placement of Hickman catheters via the percutaneous subclavian vein (SCV) route. One experienced surgeon inserted 12F, double lumen, tunnelled, silicon based catheters in the operation room via fluoroscopic control. All of the procedure related complications, morbidity and mortality were analyzed on the basis of the side of catheter insertion.

Results: The total rate of malpositioning in this series was 14.66%. The Jugular vein was the most common malpositioning site (66.6%). We observed a statistically significant difference in malpositioning between left versus right sided attempts, at 5.55% versus 20.51%, respectively (p = 0.032). The routes of malpositioning encountered for left sided attempts were the right SCV and the left internal jugular vein, the right internal jugular vein (n = 5), the left SCV vein (n = 2), and one left internal jugular vein. There was no significant difference between the right and left sided attempts for mechanical complications other than malpositioning (p < 0.05).

Conclusion: In this study the rate of malpositioning was greater in the right sided approach (p = 0.032) and the other mechanical complication rates did not differ for the two methods. Our results indicate that there is no need for hesitancy in using left sided attempts at CVC insertion.

Citing Articles

The correlation between subcutaneous fat thickness and the incidence of chemoport-related infection.

Khongyut T, Panpikoon T, Buangam C, Pichitpichatkul K, Treesit T, Feinggumloon S Infect Prev Pract. 2025; 7(1):100433.

PMID: 39758681 PMC: 11699447. DOI: 10.1016/j.infpip.2024.100433.


Factors affecting mechanical complications of central venous access devices in children.

Zhang J, Nataraja R, Lynch A, Barnes R, Ferguson P, Pacilli M Pediatr Surg Int. 2022; 38(7):1067-1073.

PMID: 35513517 PMC: 9163013. DOI: 10.1007/s00383-022-05130-1.


Pediatric surgical errors: A systematic scoping review.

Marsh K, Fleming 2nd M, Turrentine F, Levin D, Gander J, Keim-Malpass J J Pediatr Surg. 2021; 57(4):616-621.

PMID: 34366133 PMC: 8792106. DOI: 10.1016/j.jpedsurg.2021.07.019.


Influence of Cannulation Point on Infraclavicular Subclavian Vein Catheterization: A Clinical Trial.

Tarbiat M, Salimbahrami S, Khorshidi H Anesth Pain Med. 2019; 9(4):e92724.

PMID: 31754610 PMC: 6825368. DOI: 10.5812/aapm.92724.


Influence of arm position during infraclavicular subclavian vein catheterization in coronary artery bypass graft surgery.

Tarbiat M, Davoudi M, Salimbahrami S J Cardiovasc Thorac Res. 2019; 10(4):192-196.

PMID: 30680076 PMC: 6335989. DOI: 10.15171/jcvtr.2018.33.