Frequency Characterization of Blood Glucose Dynamics

Overview
Journal Ann Biomed Eng
Date 2003 Feb 8
PMID 12572659
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

Examples of the frequency range of blood glucose dynamics of normal subjects and subjects with diabetes are reported here, based on data from the literature. The frequency band edge was determined from suitable, frequently sampled blood glucose recordings using two methods: frequency domain estimation and signal reconstruction. The respective maximum acceptable sampling intervals, or Nyquist sampling periods (NSP), required to accurately represent blood glucose dynamics were calculated. Preliminary results based on the limited data available in the literature indicate that although blood glucose NSP values are higher in most diabetic subjects, values in some diabetic subjects are indistinguishable from those of normal subjects. High fidelity monitoring sufficient to follow the intrinsic blood glucose dynamics of all diabetic subjects requires a NSP of approximately 10 min, corresponding to a continuous frequency band edge of approximately 1 x 10(-3) Hz. This analysis provides key information for the design of clinical studies that include blood glucose dynamics and for the design of new glucose monitoring systems.

Citing Articles

Enabling personalized decision support with patient-generated data and attributable components.

Mitchell E, Tabak E, Levine M, Mamykina L, Albers D J Biomed Inform. 2020; 113:103639.

PMID: 33316422 PMC: 7968723. DOI: 10.1016/j.jbi.2020.103639.


The Diabits App for Smartphone-Assisted Predictive Monitoring of Glycemia in Patients With Diabetes: Retrospective Observational Study.

Kriventsov S, Lindsey A, Hayeri A JMIR Diabetes. 2020; 5(3):e18660.

PMID: 32960180 PMC: 7539161. DOI: 10.2196/18660.


Exploring the Frequency Domain of Continuous Glucose Monitoring Signals to Improve Characterization of Glucose Variability and of Diabetic Profiles.

Fico G, Hernandez L, Cancela J, Isabel M, Facchinetti A, Fabris C J Diabetes Sci Technol. 2017; 11(4):773-779.

PMID: 28627250 PMC: 5588824. DOI: 10.1177/1932296816685717.


Multicenter Observational Study of the First-Generation Intravenous Blood Glucose Monitoring System in Hospitalized Patients.

Bochicchio G, Hipszer B, Magee M, Bergenstal R, Furnary A, Gulino A J Diabetes Sci Technol. 2015; 9(4):739-50.

PMID: 26033922 PMC: 4525650. DOI: 10.1177/1932296815587939.


Point accuracy and reliability of an interstitial continuous glucose-monitoring device in critically ill patients: a prospective study.

van Hooijdonk R, Leopold J, Winters T, Binnekade J, Juffermans N, Horn J Crit Care. 2015; 19:34.

PMID: 25652770 PMC: 4382831. DOI: 10.1186/s13054-015-0757-4.