» Articles » PMID: 12512721

Maximum Likelihood Fitting of FROC Curves Under an Initial-detection-and-candidate-analysis Model

Overview
Journal Med Phys
Specialty Biophysics
Date 2003 Jan 7
PMID 12512721
Citations 26
Authors
Affiliations
Soon will be listed here.
Abstract

We have developed a model for FROC curve fitting that relates the observer's FROC performance not to the ROC performance that would be obtained if the observer's responses were scored on a per image basis, but rather to a hypothesized ROC performance that the observer would obtain in the task of classifying a set of "candidate detections" as positive or negative. We adopt the assumptions of the Bunch FROC model, namely that the observer's detections are all mutually independent, as well as assumptions qualitatively similar to, but different in nature from, those made by Chakraborty in his AFROC scoring methodology. Under the assumptions of our model, we show that the observer's FROC performance is a linearly scaled version of the candidate analysis ROC curve, where the scaling factors are just given by the FROC operating point coordinates for detecting initial candidates. Further, we show that the likelihood function of the model parameters given observational data takes on a simple form, and we develop a maximum likelihood method for fitting a FROC curve to this data. FROC and AFROC curves are produced for computer vision observer datasets and compared with the results of the AFROC scoring method. Although developed primarily with computer vision schemes in mind, we hope that the methodology presented here will prove worthy of further study in other applications as well.

Citing Articles

Evaluation of computer-aided detection and diagnosis systems.

Petrick N, Sahiner B, Armato 3rd S, Bert A, Correale L, Delsanto S Med Phys. 2013; 40(8):087001.

PMID: 23927365 PMC: 4108682. DOI: 10.1118/1.4816310.


Subject-centered free-response ROC (FROC) analysis.

Bandos A, Rockette H, Gur D Med Phys. 2013; 40(5):051706.

PMID: 23635254 PMC: 3644034. DOI: 10.1118/1.4799843.


A brief history of free-response receiver operating characteristic paradigm data analysis.

Chakraborty D Acad Radiol. 2013; 20(7):915-9.

PMID: 23583665 PMC: 3679336. DOI: 10.1016/j.acra.2013.03.001.


Evaluating imaging and computer-aided detection and diagnosis devices at the FDA.

Gallas B, Chan H, DOrsi C, Dodd L, Giger M, Gur D Acad Radiol. 2012; 19(4):463-77.

PMID: 22306064 PMC: 5557046. DOI: 10.1016/j.acra.2011.12.016.


Computer-assisted detection of infectious lung diseases: a review.

Bagci U, Bray M, Caban J, Yao J, Mollura D Comput Med Imaging Graph. 2011; 36(1):72-84.