Evaluation of Role of Bile Flow Patterns in Process of in Vitro Stent Occlusion

Overview
Journal Dig Dis Sci
Specialty Gastroenterology
Date 2002 Dec 25
PMID 12498287
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Stent placement above the sphincter of Oddi might have advantages over stent placement across the sphincter of Oddi in prolonging stent patency in the treatment for malignant obstructive jaundice. To evaluate the role of bile flow patterns corresponding to biliary stent positioning in the process of stent occlusion in an in vitro bile perfusion model, one group of polyethylene stents was perfused continuously and another group of stents was perfused with additional flushing three times a day, simulating gallbladder emptying. After 8 weeks, the flow rates through the perfused stents were measured for evaluating the extent of stent occlusion indirectly. The results showed that bile flow rate of stents with additional flushing was significantly higher than the continuously perfused stents (P < or = 0.01). It was demonstrated that after 18 hr of perfusion, additional flushing obviously decreased bacterial adherence to stent when compared to continuously perfused stents. In conclusion, flushing of bile may decrease the build-up of substance in vitro and thus improve stent flow rates, for which decreasing bacterial adherence to stents may be responsible.

Citing Articles

Initial study of sediment antagonism and characteristics of silver nanoparticle-coated biliary stents in an experimental animal model.

Tian Y, Xia M, Zhang S, Fu Z, Wen Q, Liu F Int J Nanomedicine. 2016; 11:1807-17.

PMID: 27217749 PMC: 4853005. DOI: 10.2147/IJN.S103609.


Granulation encapsulated stent: a new therapeutic approach for vascular implantation.

Tang L, Chen X, Tang S, LaLonde T, Gardin J Heart. 2006; 93(2):238-43.

PMID: 16914483 PMC: 1861384. DOI: 10.1136/hrt.2006.093765.

References
1.
Chodash H, Tsang T, POLLACK J, Eisenman R, Rege R, Ostrow J . Effect of temperature on stability of eight components of porcine gallbladder bile. Dig Dis Sci. 1997; 42(2):273-8. DOI: 10.1023/a:1018845314389. View

2.
Binmoeller K, Seitz U, Seifert H, Thonke F, Sikka S, Soehendra N . The Tannenbaum stent: a new plastic biliary stent without side holes. Am J Gastroenterol. 1995; 90(10):1764-8. View

3.
TORSOLI A . Physiology of the human sphincter of Oddi. Endoscopy. 1988; 20 Suppl 1:166-70. DOI: 10.1055/s-2007-1018169. View

4.
Leung J, Del Favero G, Cotton P . Endoscopic biliary prostheses: a comparison of materials. Gastrointest Endosc. 1985; 31(2):93-5. DOI: 10.1016/s0016-5107(85)72004-4. View

5.
Matsushita M, HAJIRO K, Takakuwa H, Nishio A . Are biliary stents placed above the sphincter of oddi really ineffective?. Gastrointest Endosc. 2000; 51(1):116-7. DOI: 10.1016/s0016-5107(00)70149-0. View