» Articles » PMID: 12413459

Toward Optimized Antibody Microarrays: a Comparison of Current Microarray Support Materials

Overview
Journal Anal Biochem
Publisher Elsevier
Specialty Biochemistry
Date 2002 Nov 5
PMID 12413459
Citations 34
Authors
Affiliations
Soon will be listed here.
Abstract

With the advent of protein and antibody microarray technology several different coatings and protocols have been published, which may be broadly divided into two types: gel-coated surfaces and plain non-gel-coated glass or plastic surfaces, some with chemical groups attached. We have screened 11 different array surfaces of both types and compared them with respect to their detection limit, inter- and intrachip variation, and storage characteristics. Five different antibodies were immobilized onto each type of microarray support, with total protein concentrations ranging from 40 fmol to 25 amol per spot. From these results, it was seen that some antibodies were more suited for use on antibody arrays. All measurements were performed in quadruplicate, and the results revealed high signal uniformity and reproducibility of most plain glass and plastic slides. Lower detection limits were obtained with polyacrylamide-coated slides, making them more suitable for the detection of very low concentrations of antigen. All microarray coatings could be stored for a period of 8 weeks; however, improved results were seen after 2 weeks of storage. In conclusion, the results indicate the need to test each antibody to be used on an antibody array and to select the microarray coating based on experimental requirements.

Citing Articles

The Simultaneous Detection of Multiple Antibiotics in Milk and Pork Based on an Antibody Chip Biosensor.

Xiao J, Wei N, Wu S, Li H, Yin X, Si Y Biosensors (Basel). 2022; 12(8).

PMID: 36004974 PMC: 9405744. DOI: 10.3390/bios12080578.


Fabrication of Biosensing Interface with Monolayers.

Tanaka M, Niwa O Anal Sci. 2021; 37(5):673-682.

PMID: 33390417 DOI: 10.2116/analsci.20SCR06.


Immunosensor Based on Antibody-Functionalized MoS for Rapid Detection of Avian Coronavirus on Cotton Thread.

Weng X, Neethirajan S IEEE Sens J. 2020; 18(11):4358-4363.

PMID: 32390783 PMC: 7186039. DOI: 10.1109/JSEN.2018.2829084.


Longitudinal Multiplexed Measurement of Quantitative Proteomic Signatures in Mouse Lymphoma Models Using Magneto-Nanosensors.

Lee J, Appelmann I, Miething C, Shultz T, Ruderman D, Kim D Theranostics. 2018; 8(5):1389-1398.

PMID: 29507628 PMC: 5835944. DOI: 10.7150/thno.20706.


Evaluation of Solid Supports for Slide- and Well-Based Recombinant Antibody Microarrays.

Gerdtsson A, Dexlin-Mellby L, Delfani P, Berglund E, Borrebaeck C, Wingren C Microarrays (Basel). 2016; 5(2).

PMID: 27600082 PMC: 5003492. DOI: 10.3390/microarrays5020016.