» Articles » PMID: 12375459

An Up to 5-year Clinical Evaluation of Posterior In-ceram CAD/CAM Core Crowns

Overview
Specialty Dentistry
Date 2002 Oct 12
PMID 12375459
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: This study evaluated the clinical performance of posterior CAD/CAM-generated In-Ceram Alumina and In-Ceram Spinell core crowns.

Materials And Methods: Nineteen In-Ceram Spinell core crowns (four premolars and 15 molars) and 24 In-Ceram Alumina core crowns (two premolars and 22 molars) in 21 patients were examined using modified USPHS criteria at baseline and after a mean service time of 39 +/- 11 months. The crown copings were machined from Vitablocs In-Ceram Alumina and Vitablocs In-Ceram Spinell using the Cerec 2 CAD/CAM system.

Results: Two molar In-Ceram Alumina core crowns fractured after respective service times of 14 and 17 months in the same patient. The Kaplan-Meier survival rate regarding fracture of the ceramic was 92% for In-Ceram Alumina and 100% for In-Ceram Spinell. At the follow-up examination, 80% alpha ratings and 18% beta ratings for In-Ceram Alumina core crowns and 84% alpha ratings and 15% beta ratings for In-Ceram Spinell core crowns were recorded.

Conclusion: Despite the two fractures, the clinical quality of CAD/CAM-generated In-Ceram Alumina and In-Ceram Spinell posterior crowns was excellent. Within the limitations of this study, both types of crowns appeared to be feasible.

Citing Articles

The incidence of dental fractures in the Italian population during the COVID-19 pandemic: An observational study.

Abdellatif D, Iandolo A, Pisano M, Fornara R, Sangiovanni G, Amato M J Conserv Dent Endod. 2024; 27(2):146-153.

PMID: 38463480 PMC: 10923222. DOI: 10.4103/JCDE.JCDE_241_23.


Finite element and in vitro study on biomechanical behavior of endodontically treated premolars restored with direct or indirect composite restorations.

Maravic T, Comba A, Mazzitelli C, Bartoletti L, Balla I, di Pietro E Sci Rep. 2022; 12(1):12671.

PMID: 35879388 PMC: 9314407. DOI: 10.1038/s41598-022-16480-0.


Marginal Integrity of CAD/CAM Ceramic Crowns Using Two Different Finish Line Designs.

Hussain Akbar J, Omar R, Al-Tarakmah Y Med Princ Pract. 2021; 30(5):443-447.

PMID: 33902029 PMC: 8562050. DOI: 10.1159/000516833.


Fracture toughness of zirconia with a nanometer size notch fabricated using focused ion beam milling.

Liao Y, Gruber M, Lukic H, Chen S, Megremis S J Biomed Mater Res B Appl Biomater. 2020; 108(8):3323-3330.

PMID: 32562464 PMC: 7586783. DOI: 10.1002/jbm.b.34668.


Three-dimensional finite element analysis of the stress distribution pattern in a mandibular first molar tooth restored with five different restorative materials.

Dsouza K, Aras M J Indian Prosthodont Soc. 2017; 17(1):53-60.

PMID: 28216846 PMC: 5308080. DOI: 10.4103/0972-4052.197938.