» Articles » PMID: 12353275

Coronary MRA with 3D Undersampled Projection Reconstruction TrueFISP

Overview
Journal Magn Reson Med
Publisher Wiley
Specialty Radiology
Date 2002 Sep 28
PMID 12353275
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

Undersampled projection reconstruction (PR) offers improved imaging efficiency allowing a relative tradeoff between signal-to-noise ratio (SNR) or streak artifact and the number of acquired k-space views rather than the tradeoff between resolution or aliasing artifact and the number of acquired k-space lines inherent to Fourier imaging techniques. TrueFISP (true fast imaging with steady state precession) is ideally suited for undersampled PR imaging because of its inherently high SNR. The purpose of this work was to investigate the feasibility of using undersampled three-dimensional (3D) PR TrueFISP for breathhold coronary artery imaging. Phantom studies and a preliminary in vivo comparison demonstrated the improved spatial resolution of PR over Fourier TrueFISP with the same imaging time. In a 24-heartbeat coronary imaging scheme, segmented 3D PR TrueFISP provided a 1.0 x 1.0 mm(2) isotropic in-plane voxel size while acquiring between 93 and 153 views per partition. Streak artifacts were present in some images but were not found to impede coronary artery delineation. In conclusion, 3D undersampled PR TrueFISP provides isotropic in-plane voxel size within a single breathhold and is a promising technique for coronary artery imaging.

Citing Articles

Myocardial arterial spin labeling.

Kober F, Jao T, Troalen T, Nayak K J Cardiovasc Magn Reson. 2016; 18:22.

PMID: 27071861 PMC: 4830031. DOI: 10.1186/s12968-016-0235-4.


Non-Contrast Enhanced MR Angiography (NCE-MRA) of the Calf: A Direct Comparison between Flow-Sensitive Dephasing (FSD) Prepared Steady-State Free Precession (SSFP) and Quiescent-Interval Single-Shot (QISS) in Patients with Diabetes.

Zhang N, Zou L, Huang Y, Liu D, Tang Y, Fan Z PLoS One. 2015; 10(6):e0128786.

PMID: 26035645 PMC: 4452776. DOI: 10.1371/journal.pone.0128786.


Non-ECG-gated myocardial perfusion MRI using continuous magnetization-driven radial sampling.

Sharif B, Dharmakumar R, Arsanjani R, Thomson L, Merz C, Berman D Magn Reson Med. 2014; 72(6):1620-8.

PMID: 24443160 PMC: 4102672. DOI: 10.1002/mrm.25074.


Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3 T with radial EPI.

Bhat H, Yang Q, Zuehlsdorff S, Li K, Li D Magn Reson Med. 2011; 66(1):82-91.

PMID: 21305601 PMC: 3120915. DOI: 10.1002/mrm.22781.


Contrast-kinetics-resolved whole-heart coronary MRA using 3DPR.

Lai P, Huang F, Li Y, Nielles-Vallespin S, Bi X, Jerecic R Magn Reson Med. 2010; 63(4):970-8.