Evaluation of Kodak EDR2 Film for Dose Verification of Intensity Modulated Radiation Therapy Delivered by a Static Multileaf Collimator

Overview
Journal Med Phys
Specialty Biophysics
Date 2002 Aug 31
PMID 12201414
Citations 31
Authors
Affiliations
Soon will be listed here.
Abstract

A new type of radiographic film, Kodak EDR2 film, was evaluated for dose verification of intensity modulated radiation therapy (IMRT) delivered by a static multileaf collimator (SMLC). A sensitometric curve of EDR2 film irradiated by a 6 MV x-ray beam was compared with that of Kodak X-OMAT V (XV) film. The effects of field size, depth and dose rate on the sensitometric curve were also studied. It is found that EDR2 film is much less sensitive than XV film. In high-energy x-ray beams, the double hit process is the dominant mechanism that renders the grains on EDR2 films developable. As a result, in the dose range that is commonly used for film dosimetry for IMRT and conventional external beam therapy, the sensitometric curves of EDR2 films cannot be approximated as a linear function, OD = c * D. Within experimental uncertainty, the film sensitivity does not depend on the dose rate (50 vs 300 MU/min) or dose per pulse (from 1.0 x 10(-4) to 4.21 x 10(-4) Gy/pulse). Field sizes and depths (up to field size of 10 x 10 cm2 and depth = 10 cm) have little effect on the sensitometric curves. Percent depth doses (PDDs) for both 6 and 23 MV x rays were measured with both EDR2 and XV films and compared with ion chamber data. Film data are within 2.5% of the ion chamber results. Dose profiles measured with EDR2 film are consistent with those measured with an ion chamber. Examples of measured IMRT isodose distributions versus calculated isodoses are presented. We have used EDR2 films for verification of all IMRT patients treated by SMLC in our clinic. In most cases, with EDR2 film, actual clinical daily fraction doses can be used for verification of composite isodose distributions of SMLC-based IMRT.

Citing Articles

Development of a novel delivery quality assurance system based on simultaneous verification of dose distribution and binary multi-leaf collimator opening in helical tomotherapy.

Tanaka Y, Hashimoto M, Ishigami M, Nakano M, Hasegawa T Radiat Oncol. 2023; 18(1):180.

PMID: 37919745 PMC: 10621123. DOI: 10.1186/s13014-023-02366-6.


Experimental dosimetry of EDR2 films in scanning carbon-ion irradiation.

Wang W, Deng Y, Huang Z J Appl Clin Med Phys. 2022; 23(7):e13636.

PMID: 35594015 PMC: 9278678. DOI: 10.1002/acm2.13636.


Different Dosimeters/Detectors Used in Small-Field Dosimetry: Pros and Cons.

Parwaie W, Refahi S, Ardekani M, Farhood B J Med Signals Sens. 2018; 8(3):195-203.

PMID: 30181968 PMC: 6116321. DOI: 10.4103/jmss.JMSS_3_18.


Absolute dose verification of static intensity modulated radiation therapy (IMRT) with ion chambers of various volumes and TLD detectors.

Acun-Bucht H, Tuncay E, Darendeliler E, Kemikler G Rep Pract Oncol Radiother. 2018; 23(4):242-250.

PMID: 29991928 PMC: 6035899. DOI: 10.1016/j.rpor.2018.04.001.


Evaluating the Impact of Various Parameters on the Gamma Index Values of 2D Diode Array in IMRT Verification.

Jabbari K, Pashaei F, Ay M, Amouheidari A, Tavakoli M J Med Signals Sens. 2018; 8(1):31-38.

PMID: 29535922 PMC: 5840894. DOI: 10.4103/jmss.JMSS_15_17.