Abstract

A novel renewable reagentless hydrogen peroxide (H(2)O(2)) sensor based on the direct electron transfer of horseradish peroxidase (HRP) is proposed. The direct electrochemistry of HRP immobilized on a colloidal gold-modified carbon paste electrode (Au-CPE) was investigated using electrochemical methods. The immobilized HRP displayed a pair of redox peaks in 0.1M phosphate buffer (PB), pH 7.0, with a formal potential of -0.346 V. The response showed a surface-controlled electrode process with an electron transfer rate constant of 6.04+/-0.18s(-1) determined in the scan rate range from 120 to 500 mV/s. The biosensor displayed an excellent electrocatalytic response to the reduction of H(2)O(2) without the aid of an electron mediator. The sensor surface could be renewed quickly and reproducibly by a simple polish step. The calibration range of H(2)O(2) was 0-0.3mM with linear relation from 0.48 to 50 microM and a detection limit of 0.21 microM at 3 sigma. The response showed Michaelis-Menten behavior at higher H(2)O(2) concentrations. The K(app)(M) value of HRP at HRP-Au-CPE was determined to be 3.69+/-0.71 mM.

Citing Articles

A Multicomponent Polymer-Metal-Enzyme System as Electrochemical Biosensor for HO Detection.

Tong P, Asif M, Ajmal M, Aziz A, Sun Y Front Chem. 2022; 10:874965.

PMID: 35572115 PMC: 9099068. DOI: 10.3389/fchem.2022.874965.


Electrodeposition of silver onto carbon graphite and their catalysis properties toward thiamethoxam reduction: application in food and beverage samples.

Ajermoun N, Lahrich S, Farahi A, Bakasse M, Saqrane S, El Mhammedi M Heliyon. 2020; 6(12):e05784.

PMID: 33376826 PMC: 7758523. DOI: 10.1016/j.heliyon.2020.e05784.


Electrochemical Determination of Norepinephrine by Means of Modified Glassy Carbon Electrodes with Carbon Nanotubes and Magnetic Nanoparticles of Cobalt Ferrite.

Queiroz D, Dadamos T, Machado S, Martines M Sensors (Basel). 2018; 18(4).

PMID: 29659556 PMC: 5948746. DOI: 10.3390/s18041223.


Development of Amperometric Hydrogen Peroxide Sensor Based on Horseradish Peroxidase-Immobilized Poly(Thiophene-co-EpoxyThiophene).

Kim H, Piao M, Choi S, Shin C, Lee Y Sensors (Basel). 2016; 8(7):4110-4118.

PMID: 27879925 PMC: 3697164. DOI: 10.3390/s8074110.


Direct electrochemistry of hemoglobin immobilized on a functionalized multi-walled carbon nanotubes and gold nanoparticles nanocomplex-modified glassy carbon electrode.

Hong J, Zhao Y, Xiao B, Moosavi-Movahedi A, Ghourchian H, Sheibani N Sensors (Basel). 2013; 13(7):8595-611.

PMID: 23881129 PMC: 3758613. DOI: 10.3390/s130708595.