The objective of this study was to investigate whether the use of an electronic apex locator results in a reduction in X-ray exposure during endodontic therapy. Fifty, sound, extracted, single-rooted canine and incisor teeth were selected and randomly divided into two groups (A and B) of 25 teeth. The working length was determined radiographically with (group B) and without (group A) adjunctive use of an apex locator by one operator. After working length determination, the teeth were sectioned and the actual working length measured for comparison. For group A, 14 retake radiographs were required to determine the working length, whereas group B required no retake radiographs; this difference was highly significant (p < 0.001). The electronic apex locator was extremely accurate in locating the apical foramen with all teeth tested within 0.5 mm of the anatomical apex and 11 (44%) teeth at the apical foramen. In contrast, 15 (60%) teeth tested using radiographs alone were within 0.5 mm of the anatomical apex and only 4 (16%) teeth were actually at the anatomical apex. It was concluded that using an electronic apex locator as an aid to endodontic therapy could potentially reduce the number of diagnostic radiographs required for working length determination. Location of the apical foramen using a combination of an electronic apex locator and radiographs to determine working length is more accurate than using radiographs alone.

Citing Articles

Efficacy of electronic apex locators in comparison with intraoral radiographs in working length determination- a systematic review and meta-analysis.

Kaur G, Thomas A, Sarah Samson R, Varghese E, Ponraj R, Nagraj S BMC Oral Health. 2024; 24(1):532.

PMID: 38704529 PMC: 11069301. DOI: 10.1186/s12903-024-04259-w.


Comparative evaluation of root ZX Mini® apex locator and radiovisiography in determining the working length of primary molars: An In Vivo study.

Davalbhakta R, Gokhale N, Hugar S, Badakar C, Gowtham A, Soneta S J Oral Biol Craniofac Res. 2021; 11(2):257-262.

PMID: 33680750 PMC: 7918273. DOI: 10.1016/j.jobcr.2021.02.007.


A Comparative Evaluation of Efficacy of Electronic Apex Locator, Digital Radiography, and Conventional Radiographic Method for Root Canal Working Length Determination in Primary Teeth: An Study.

Sahni A, Kapoor R, Gandhi K, Kumar D, Datta G, Malhotra R Int J Clin Pediatr Dent. 2021; 13(5):523-528.

PMID: 33623342 PMC: 7887167. DOI: 10.5005/jp-journals-10005-1821.


Evaluation of the accuracy of different apex locators in determining the working length during root canal retreatment.

Tufenkci P, Kalayci A J Dent Res Dent Clin Dent Prospects. 2020; 14(2):125-129.

PMID: 32908654 PMC: 7464225. DOI: 10.34172/joddd.2020.026.


Comparative evaluation of the accuracy of two electronic apex locators in determining the working length in teeth with simulated apical root resorption: An in vitro study.

Saraswathi V, Kedia A, Purayil T, Ballal V, Saini A J Conserv Dent. 2016; 19(5):402-5.

PMID: 27656055 PMC: 5026096. DOI: 10.4103/0972-0707.190002.