Image Distortion Correction in EPI: Comparison of Field Mapping with Point Spread Function Mapping

Overview
Journal Magn Reson Med
Publisher Wiley
Specialty Radiology
Date 2002 Jul 12
PMID 12111941
Citations 93
Authors
Affiliations
Soon will be listed here.
Abstract

Echo-planar imaging (EPI) can provide rapid imaging by acquiring a complete k-space data set in a single acquisition. However, this approach suffers from distortion effects in geometry and intensity, resulting in poor image quality. The distortions, caused primarily by field inhomogeneities, lead to intensity loss and voxel shifts, the latter of which are particularly severe in the phase-encode direction. Two promising approaches to correct the distortion in EPI are field mapping and point spread function (PSF) mapping. The field mapping method measures the field distortions and translates these into voxel shifts, which can be used to assign image intensities to the correct voxel locations. The PSF approach uses acquisitions with additional phase-encoding gradients applied in the x, y, and/or z directions to map the 1D, 2D, or 3D PSF of each voxel. These PSFs encode the spatial information about the distortion and the overall distribution of intensities from a single voxel. The measured image is the convolution of the undistorted density and the PSF. Measuring the PSF allows the distortion in geometry and intensity to be corrected. This work compares the efficacy of these methods with equal time allowed for field mapping and PSF mapping.

Citing Articles

Romer-EPTI: Rotating-view motion-robust super-resolution EPTI for SNR-efficient distortion-free in-vivo mesoscale diffusion MRI and microstructure imaging.

Dong Z, Reese T, Lee H, Huang S, Polimeni J, Wald L Magn Reson Med. 2024; 93(4):1535-1555.

PMID: 39552568 PMC: 11782731. DOI: 10.1002/mrm.30365.


3D distortion-free, reduced FOV diffusion-prepared gradient echo at 3 T.

McElroy S, Tomi-Tricot R, Cleary J, Tan H, Kinsella S, Jeljeli S Magn Reson Med. 2024; 93(4):1471-1483.

PMID: 39462469 PMC: 11782725. DOI: 10.1002/mrm.30357.


Comparison of single shot and multishot diffusion-weighted imaging in 5-T magnetic resonance imaging for brain disease diagnosis.

Chen H, Tang R, Song X, Zong R, Liu J, Jin C Quant Imaging Med Surg. 2024; 14(10):7291-7305.

PMID: 39429579 PMC: 11485352. DOI: 10.21037/qims-24-118.


Practical utilization of nonlinear spatial encoding: Fast field mapping and FRONSAC-wave.

Zhang H, Constable R, Galiana G Magn Reson Med. 2024; 92(3):1035-1047.

PMID: 38651264 PMC: 11209788. DOI: 10.1002/mrm.30119.


Romer-EPTI: rotating-view motion-robust super-resolution EPTI for SNR-efficient distortion-free in-vivo mesoscale dMRI and microstructure imaging.

Dong Z, Reese T, Lee H, Huang S, Polimeni J, Wald L bioRxiv. 2024; .

PMID: 38352481 PMC: 10862730. DOI: 10.1101/2024.01.26.577343.