A Performance Comparison of Flat-panel Imager-based MV and KV Cone-beam CT
Overview
Affiliations
The use of cone-beam computed tomography (CBCT) has been proposed for guiding the delivery of radiation therapy, and investigators have examined the use of both kilovoltage (kV) and megavoltage (MV) x-ray beams in the development of such CBCT systems. In this paper, the inherent contrast and signal-to-noise ratio (SNR) performance for a variety of existing and hypothetical detectors for CBCT are investigated analytically as a function of imaging dose and object size. Theoretical predictions are compared to the results of experimental investigations employing largearea flat-panel imagers (FPIs) at kV and MV energies. Measurements were performed on two different FPI-based CBCT systems: a bench-top prototype incorporating an FPI and kV x-ray source (100 kVp x rays), and a system incorporating an FPI mounted on the gantry of a medical linear accelerator (6 MV x rays). The SNR in volume reconstructions was measured as a function of dose and found to agree reasonably with theoretical predictions. These results confirm the theoretically predicted advantages of employing kV energy x rays in imaging soft-tissue structures found in the human body. While MV CBCT may provide a valuable means of correcting 3D setup errors and may offer an advantage in terms of simplicity of mechanical integration with a linear accelerator (e.g., implementation in place of a portal imager), kV CBCT offers significant performance advantages in terms of image contrast and SNR per unit dose for visualization of soft-tissue structures. The relatively poor SNR performance at MV energies is primarily a result of the low x-ray quantum efficiencies (approximately a few percent or less) that are currently achieved with FPIs at high energies. Furthermore, kV CBCT with an FPI offers the potential of combined volumetric and radiographic/fluoroscopic imaging using the same device.
Utility of photon-counting detectors for MV-kV dual-energy computed tomography imaging.
Jadick G, Ventura M, La Riviere P J Med Imaging (Bellingham). 2024; 11(Suppl 1):S12811.
PMID: 39735347 PMC: 11670364. DOI: 10.1117/1.JMI.11.S1.S12811.
Yadegari A, Safi Y, Shahbazi S, Yaghoutiazar S, Ahsaie M Dentomaxillofac Radiol. 2023; 52(8):20230187.
PMID: 37874074 PMC: 10968765. DOI: 10.1259/dmfr.20230187.
Shields B, Ramachandran P Phys Eng Sci Med. 2023; 46(3):1321-1330.
PMID: 37462889 PMC: 10480263. DOI: 10.1007/s13246-023-01302-y.
Impact of a novel multilayer imager on metal artifacts in MV-CBCT.
Harris T, Jacobson M, Myronakis M, Lehmann M, Huber P, Morf D Phys Med Biol. 2023; 68(14).
PMID: 37343590 PMC: 10382207. DOI: 10.1088/1361-6560/ace09a.
4DCT is long overdue for improvement.
Tryggestad E, Li H, Rong Y J Appl Clin Med Phys. 2023; 24(4):e13933.
PMID: 36866617 PMC: 10113694. DOI: 10.1002/acm2.13933.