» Articles » PMID: 12062606

Skin Toxicity Due to Intensity-modulated Radiotherapy for Head-and-neck Carcinoma

Overview
Specialties Oncology
Radiology
Date 2002 Jun 14
PMID 12062606
Citations 61
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To investigate the cause of acute skin toxicity observed in the treatment of head-and-neck cancer with extended-field intensity-modulated radiotherapy (EF-IMRT).

Methods And Materials: EF-IMRT was used to treat head-and-neck cancer, with the gross target volume receiving 70 Gy and the clinical target volume 60 Gy. A thermoplastic mask covering the head, neck, and shoulder was used for immobilization. Dosimetric studies were conducted to investigate the possible causes of the skin reactions, such as the bolus effect of the mask, the use of multiple tangential beams with IMRT plans, and the way in which the physicians contoured the lymph nodes. The dose-volume histograms of conventional opposed-lateral fields were compared with that of the multiple tangential EF-IMRT fields. IMRT plans with neck nodes contoured up to and including the skin surface were compared with plans that contoured the neck nodes 5 mm away from the skin surface. In addition, IMRT plans defining the skin as a sensitive structure were compared with plans that did not define the skin as a sensitive structure. All plans were created using an anthropomorphic Rando phantom, and the skin doses were measured with and without the mask. In each measurement, 6 thermoluminescent dosimeters (TLDs) were placed at the lateral and medial surfaces of the neck.

Results: For all four plans, the measured skin doses with the mask were consistently higher than those without the mask. The average dose increase was about 18% owing to the bolus effect of the mask. Multiple tangential fields used in IMRT plans contributed to an increase in skin dose by about 19% and 27%, with and without the mask, respectively. If the skin of the neck was contoured as a sensitive structure for dose optimization, the volume of skin that received >45 Gy was further reduced by about 20%. Five patients immobilized with head and shoulder masks were treated with EF-IMRT plans with the neck nodes carefully delineated away from the skin surface. The neck skin was identified as a sensitive structure for dose optimization. Grade 1 toxicity was observed in 3 patients, Grade 2 in 1 patient, and Grade 3 in 1 patient toward the end of treatment.

Conclusion: Multiple factors contributed to the observed acute skin reaction for head-and-neck cancer patients treated with EF-IMRT. By taking into consideration the skin as a sensitive structure during inverse planning, it was possible to reduce the skin dose to a tolerable level without compromising tumor target coverage.

Citing Articles

Hydrogel and scalp/skin conductivities impact dose from tumor treating fields.

Lok E, Liang O, Haack M, Wong E Front Bioeng Biotechnol. 2025; 13:1484317.

PMID: 40066359 PMC: 11891368. DOI: 10.3389/fbioe.2025.1484317.


The potential of thermal imaging as an early predictive biomarker of radiation dermatitis during radiotherapy for head and neck cancer: a prospective study.

Park Y, Choi S, Cho M, Son J, Kim C, Han M BMC Cancer. 2025; 25(1):309.

PMID: 39979858 PMC: 11844184. DOI: 10.1186/s12885-025-13734-8.


Correlation of degree of acute radiation dermatitis (RD) with skin dose distribution in head and neck squamous cell carcinoma patients treated with definitive concurrent chemoradiation.

Basu S, Chatterjee S, Chatterjee K, Samanta S, Saha S, Hossain S Rep Pract Oncol Radiother. 2025; 29(5):579-587.

PMID: 39759562 PMC: 11698550. DOI: 10.5603/rpor.102824.


Chronotherapy in head and neck cancer: A systematic review and meta-analysis.

Abusamak M, Abu-Samak A, Cai W, Al-Waeli H, Al-Hamed F, Al-Tamimi M Int J Cancer. 2024; 156(5):1015-1032.

PMID: 39508699 PMC: 11701392. DOI: 10.1002/ijc.35234.


Bolus Effect Caused by Use of Thermoplastic Masks in Head and Neck Radiotherapy Treatments.

Barajas-Lopez D, Castellanos-Jerez C, Diaz-Merchan J, Martinez-Ovalle S Int J Mol Sci. 2024; 25(16).

PMID: 39201819 PMC: 11354977. DOI: 10.3390/ijms25169133.