» Articles » PMID: 12043795

Model-based Technique for the Measurement of Skin Thickness in Mammography

Overview
Publisher Springer
Date 2002 Jun 5
PMID 12043795
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

A model-based method is proposed for the measurement of breast skin thickness from digitised mammograms that takes into account both the geometric and radiographic properties of the skin region. The method initially identifies a salient feature that discriminates the skin from the other anatomical structures of the breast. Its identification is based on a multi-scale grey-level gradient estimation, using a wavelet decomposition of the image. The spatial distribution of this feature is organised as a graph, with each of its nodes associated with a binary set of interpretation labels. A Markov random field is defined on the set of labels, and the best graph labelling is finally determined with a maximum a posteriori (MAP) probability criterion. The method was applied on 11 mammograms with improved contrast characteristics at the breast periphery, obtained by an exposure equalisation technique during image acquisition. The validation of the approach was performed by calculating the root mean square (RMS) error between the detected skin thickness and manual measurements performed on each of the films. The resulting error values ranged from 0.1 mm to 0.2 mm for normal cases and reached a maximum of 0.5mm in pathological cases with advanced skin thickening.

Citing Articles

Lens opacity detection for serious posterior subcapsular cataract.

Zhang W, Li H Med Biol Eng Comput. 2016; 55(5):769-779.

PMID: 27491802 DOI: 10.1007/s11517-016-1554-1.

References
1.
Skiadopoulos S, Pierrakeas C, Costaridou L, Kalogeropoulou C, Panayiotakis G . A phantom-based evaluation of an exposure equalization technique in mammography. Br J Radiol. 2000; 72(862):977-85. DOI: 10.1259/bjr.72.862.10673949. View

2.
Davies D, Dance D . The automatic computer detection of subtle calcifications in radiographically dense breasts. Phys Med Biol. 1992; 37(6):1385-90. DOI: 10.1088/0031-9155/37/6/014. View

3.
Byng J, Critten J, Yaffe M . Thickness-equalization processing for mammographic images. Radiology. 1997; 203(2):564-8. DOI: 10.1148/radiology.203.2.9114122. View

4.
Kocsis O, Costaridou L, Efstathopoulos E, Lymberopoulos D, Panayiotakis G . A tool for designing digital test objects for module performance evaluation in medical digital imaging. Med Inform Internet Med. 2000; 24(4):291-308. DOI: 10.1080/146392399298311. View

5.
Canny J . A computational approach to edge detection. IEEE Trans Pattern Anal Mach Intell. 2011; 8(6):679-98. View