High-frequency Noise in Dentistry

Overview
Date 2002 Apr 27
PMID 11975661
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Earlier studies have revealed that dentists have higher hearing thresholds than expected. The aim of this study was to evaluate the noise levels of current dentistry equipment under very controlled conditions. This noise study was carried out in the Acoustics Laboratory of Kuopio Regional Institute of Occupational Health, the background noise of which is about 0 dB(A). Working noise was simulated by drilling a polyacetal plate. During drilling and idling, the noise of the hand pieces was measured over a reflecting plane on the hemisphere surface, the radius of which was 0.3 m, and 10 noise samples were picked for each hand piece. The average sound pressure level and the sound power level of the devices were calculated applying the standard ISO 3744. The measurement and analysis were done in the one-third octave bands of 25-80,000 Hz. The measuring instruments used were the B&K 4135 microphones, the B&K 2633 preamplifiers, the B&K 2811 multiplexer, and the B&K 2133 real-time analyzer with the ZT 0318 high-frequency expansion unit. During the simulated work, the average A-weighted sound pressure level of the new and old hand pieces was 76-82 dB(A), that of the power suction tube 77 dB(A), the saliva suction tube 75 dB(A), and the ultrasonic scaler 83 dB(A). The average ultrasound level of the ultrasonic scaler was 107 dB at the one-third octave band of 25,000 Hz.

Citing Articles

Should Dentists Mandatorily Wear Ear Protection Device to Prevent Occupational Noise-induced Hearing Loss? A Randomized Case-Control Study.

Mohan K, Chopra A, Guddattu V, Singh S, Upasana K J Int Soc Prev Community Dent. 2022; 12(5):513-523.

PMID: 36532321 PMC: 9753927. DOI: 10.4103/jispcd.JISPCD_28_22.


Are dental hygienists at risk for noise-induced hearing loss? A literature review.

Henneberry K, Hilland S, Haslam S Can J Dent Hyg. 2021; 55(2):110-119.

PMID: 34221035 PMC: 8219068.


Effects of mechanical ventilation and portable air cleaner on aerosol removal from dental treatment rooms.

Ren Y, Huang Q, Marzouk T, Richard R, Pembroke K, Martone P J Dent. 2021; 105:103576.

PMID: 33388387 PMC: 7834919. DOI: 10.1016/j.jdent.2020.103576.


Assessment of occupational noise-related hearing impairment among dental health personnel.

Al-Omoush S, Abdul-Baqi K, Zuriekat M, Alsoleihat F, Elmanaseer W, Jamani K J Occup Health. 2019; 62(1):e12093.

PMID: 31674128 PMC: 6970390. DOI: 10.1002/1348-9585.12093.


An exploratory study of noise exposures in educational and private dental clinics.

Burk A, Neitzel R J Occup Environ Hyg. 2016; 13(10):741-9.

PMID: 27077918 PMC: 4992430. DOI: 10.1080/15459624.2016.1177646.