» Articles » PMID: 11954764

Intraspinal Migration of a Kirschner Wire 3 Months After Clavicular Fracture Fixation

Overview
Journal Neurosurg Rev
Specialty Neurosurgery
Date 2002 Apr 17
PMID 11954764
Citations 23
Authors
Affiliations
Soon will be listed here.
Abstract

The authors describe a patient who had Kirschner (K-) wire osteosynthesis of a right lateral clavicular fracture and developed a tetraparesis after 3 months. Plain X-ray and CT scan showed an intraspinal migration of one K-wire through the intervertebral foramen of C5/6. The K-wire was pulled out through an opening of the wound over the right clavicle. No CSF fistula was seen. The patient recovered without any postoperative neurological deficit. Patients with K-wire osteosynthesis should be informed about the risk of dislocation and wandering and should regularly be seen in the outpatient clinic. Regular X-rays should be performed. The K-wires must be sufficiently bent at the distal end to prevent wandering into the proximal direction. The K-wires should be removed soon after 6 weeks and, in cases of dislocation and migration, as early as possible.

Citing Articles

How can osteosynthesis material used for fracture fixation undergo intrathoracic migration?-a systematic literature review.

Van Dyck R, Decker G J Thorac Dis. 2024; 16(11):8068-8087.

PMID: 39678861 PMC: 11635253. DOI: 10.21037/jtd-24-943.


Distant migration of a broken guide pin following femoral neck fixation: a case report.

Amouzadeh Omrani F, Afzal S, Baroutkoub M, Barati H, Azadnajafabad S, Keipour A J Med Case Rep. 2024; 18(1):519.

PMID: 39488715 PMC: 11531691. DOI: 10.1186/s13256-024-04868-7.


Transforaminal Migration of K-Wire From Clavicle to Cervical Spinal Canal: A Case Report and Review of Literature.

Venkataramana K, Sreenivas K, Iytha M, Abraham V J Orthop Case Rep. 2024; 14(10):96-101.

PMID: 39381303 PMC: 11458248. DOI: 10.13107/jocr.2024.v14.i10.4824.


Outcomes following fixation of distal clavicle fractures utilizing arthroscopically assisted coracoclavicular ligament stabilization with a suspensory endobutton and cerclage tape.

Campbell B, Petrucelli P, Kearns K JSES Rev Rep Tech. 2024; 4(3):393-397.

PMID: 39161466 PMC: 11331726. DOI: 10.1016/j.xrrt.2024.02.003.


[Combined intrapulmonary/intramediastinal K-wire position after K-wire osteosynthesis of the clavicle : A case report].

Youssef Y, Melcher P, Steinert M, Metelmann I, Hepp P, Theopold J Unfallchirurgie (Heidelb). 2022; 126(7):581-585.

PMID: 35833973 PMC: 10319654. DOI: 10.1007/s00113-022-01217-5.