Objective: To evaluate the risk factors, type, and frequency of complications during video-EEG monitoring with subdural grid electrodes.

Methods: The authors retrospectively reviewed the records of all patients who underwent invasive monitoring with subdural grid electrodes (n = 198 monitoring sessions on 187 patients; median age: 24 years; range: 1 to 50 years) at the Cleveland Clinic Foundation from 1980 to 1997.

Results: From 1980 to 1997, the complication rate decreased (p = 0.003). In the last 5 years, 19/99 patients (19%) had complications, including two patients (2%) with permanent sequelae. In the last 3 years, the complication rate was 13.5% (n = 5/37) without permanent deficits. Overall, complications occurred during 52 monitoring sessions (26.3%): infection (n = 24; 12.1%), transient neurologic deficit (n = 22; 11.1%), epidural hematoma (n = 5; 2.5%), increased intracranial pressure (n = 5; 2.5%), and infarction (n = 3; 1.5%). One patient (0.5%) died during grid insertion. Complication occurrence was associated with greater number of grids/electrodes (p = 0.021/p = 0.052; especially >60 electrodes), longer duration of monitoring (p = 0.004; especially >10 days), older age of the patient (p = 0.005), left-sided grid insertion (p = 0.01), and burr holes in addition to the craniotomy (p = 0.022). No association with complications was found for number of seizures, IQ, anticonvulsants, or grid localization.

Conclusions: Invasive monitoring with grid electrodes was associated with significant complications. Most of them were transient. Increased complication rates were related to left-sided grid insertion and longer monitoring with a greater number of electrodes (especially more than 60 electrodes). Improvements in grid technology, surgical technique, and postoperative care resulted in significant reductions in the complication rate.

Citing Articles

Advancements in Surgical Therapies for Drug-Resistant Epilepsy: A Paradigm Shift towards Precision Care.

Zhong C, Yang K, Wang N, Yang L, Yang Z, Xu L Neurol Ther. 2025; 14(2):467-490.

PMID: 39928287 PMC: 11906941. DOI: 10.1007/s40120-025-00710-4.


Laser Welding of Micro-Wire Stent Electrode as a Minimally Invasive Endovascular Neural Interface.

Wen B, Shen L, Kang X Micromachines (Basel). 2025; 16(1).

PMID: 39858677 PMC: 11767702. DOI: 10.3390/mi16010021.


Endovascular electroencephalography (eEEG) can detect the laterality of epileptogenic foci as accurately as subdural electrodes.

Fujimoto A, Matsumaru Y, Masuda Y, Sato K, Hatano K, Numoto S Heliyon. 2024; 10(3):e25567.

PMID: 38327423 PMC: 10847992. DOI: 10.1016/j.heliyon.2024.e25567.


Electroencephalography-functional magnetic resonance imaging for clinical evaluation in focal epilepsy.

Ikemoto S, Pana R, von Ellenrieder N, Gotman J Epilepsia Open. 2023; 9(1):84-95.

PMID: 37724422 PMC: 10839335. DOI: 10.1002/epi4.12829.


Spike patterns surrounding sleep and seizures localize the seizure-onset zone in focal epilepsy.

Conrad E, Revell A, Greenblatt A, Gallagher R, Pattnaik A, Hartmann N Epilepsia. 2022; 64(3):754-768.

PMID: 36484572 PMC: 10045742. DOI: 10.1111/epi.17482.