» Articles » PMID: 11777196

Development of Generic Liquid Chromatography-mass Spectrometry Methods Using Experimental Design

Overview
Specialty Chemistry
Date 2002 Jan 5
PMID 11777196
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Standard approaches to development of liquid chromatography-mass spectrometry (LC-MS) methods, either ion-pairing or reversed-phase liquid chromatography, have been through trial and error or intentional variation of experimental factors. These approaches to method optimization fail to take into account interactions between experimental factors and therefore the results may not be optimal for the combination of experimental factors. Another approach to optimization is through the use of chemometrics. Chemometric approaches can be more efficient than trial and error or intentional variation because chemometrics make use of multivariate designs; experimental factors are varied simultaneously at the various levels. Therefore chemometrics can take into account interactions between factors. The goal of this study was to develop a generic ion-pair LC-MS method for the analysis of acidic compounds using a chemometric approach called design of experiments (DOE). Four acidic compounds which cover three classes of acidic functional groups: 1-naphthyl phosphate (1), 1-naphthalenesulfonic acid (2), 2-naphthalenesulfonic acid (3), and (1-naphthoxy)acetic acid (4) were used as model compounds to develop the generic method. This study illustrates that LC-MS conditions can be optimized efficiently with minimal amount of experimentation using a chemometric approach to experimental design.

Citing Articles

A Highly Efficient Workflow for Detecting and Identifying Sequence Variants in Therapeutic Proteins with a High Resolution LC-MS/MS Method.

Cadang L, Tam C, Moore B, Fichtl J, Yang F Molecules. 2023; 28(8).

PMID: 37110623 PMC: 10144261. DOI: 10.3390/molecules28083392.


Global optimization of the infrared matrix-assisted laser desorption electrospray ionization (IR MALDESI) source for mass spectrometry using statistical design of experiments.

Barry J, Muddiman D Rapid Commun Mass Spectrom. 2011; 25(23):3527-36.

PMID: 22095501 PMC: 3781580. DOI: 10.1002/rcm.5262.


Optimization and comparison of ESI and APCI LC-MS/MS methods: a case study of Irgarol 1051, Diuron, and their degradation products in environmental samples.

Maragou N, Thomaidis N, Koupparis M J Am Soc Mass Spectrom. 2011; 22(10):1826-38.

PMID: 21952896 DOI: 10.1007/s13361-011-0191-z.


Applicability of Generic Assays Based on Liquid Chromatography-Electrospray Mass Spectrometry to Study in vitro Metabolism of 55 Structurally Diverse Compounds.

Rousu T, Hokkanen J, Pelkonen O, Tolonen A Front Pharmacol. 2011; 1:10.

PMID: 21607061 PMC: 3095372. DOI: 10.3389/fphar.2010.00010.


Design-of-experiment optimization of exhaled breath condensate analysis using a miniature differential mobility spectrometer (DMS).

Molina M, Zhao W, Sankaran S, Schivo M, Kenyon N, Davis C Anal Chim Acta. 2008; 628(2):155-61.

PMID: 18929003 PMC: 2600869. DOI: 10.1016/j.aca.2008.09.010.

References
1.
Koppen B, Spliid N . Determination of acidic herbicides using liquid chromatography with pneumatically assisted electrospray ionization mass spectrometric and tandem mass spectrometric detection. J Chromatogr A. 1998; 803(1-2):157-68. DOI: 10.1016/s0021-9673(97)01219-3. View

2.
Siouffi A, Phan-Tan-Luu R . Optimization methods in chromatography and capillary electrophoresis. J Chromatogr A. 2000; 892(1-2):75-106. DOI: 10.1016/s0021-9673(00)00247-8. View

3.
Jemal M, Almond R, Ouyang Z, Teitz D . Negative ion electrospray high-performance liquid chromatography-mass spectrometry method development for determination of a highly polar phosphonic acid/sulfonic acid compound in plasma. Optimization of ammonium acetate concentration and in-source.... J Chromatogr B Biomed Sci Appl. 1998; 703(1-2):167-75. DOI: 10.1016/s0378-4347(97)00427-1. View

4.
Uesugi T, Sano K, Uesawa Y, Ikegami Y, Mohri K . Ion-pair reversed-phase high-performance liquid chromatography of adenine nucleotides and nucleoside using triethylamine as a counterion. J Chromatogr B Biomed Sci Appl. 1998; 703(1-2):63-74. DOI: 10.1016/s0378-4347(97)00430-1. View

5.
Witters E, Van Dongen W, Esmans E, van Onckelen H . Ion-pair liquid chromatography-electrospray mass spectrometry for the analysis of cyclic nucleotides. J Chromatogr B Biomed Sci Appl. 1997; 694(1):55-63. DOI: 10.1016/s0378-4347(96)00538-5. View