The purpose of this study was to develop coils for MR imaging of the head and neck region, with the aim of improving sensitivity and coverage. A head and neck phased array coil was constructed and compared with volume and temporomandibular joint surface coils for sensitivity and coverage in phantom studies. An algorithm was implemented to correct for the nonuniformity in the surface coil reception profile. Its application to high-resolution T2-weighted imaging in healthy volunteers was investigated.

Citing Articles

Comparison between whole-body and head and neck neurovascular coils for 3-T magnetic resonance proton resonance frequency shift thermography guidance in the head and neck region.

Ginat D, Anthony G, Christoforidis G, Oto A, Dalag L, Sammet S Lasers Med Sci. 2017; 33(2):369-373.

PMID: 29224048 DOI: 10.1007/s10103-017-2397-1.


Signal-to-noise ratio and parallel imaging performance of commercially available phased array coils in 3.0 T brain magnetic resonance imaging.

Yoshida T, Shirata K, Urikura A, Ito M, Nakaya Y Radiol Phys Technol. 2015; 8(2):305-11.

PMID: 26009490 DOI: 10.1007/s12194-015-0321-6.


Design and numerical evaluation of a volume coil array for parallel MR imaging at ultrahigh fields.

Pang Y, Wong E, Yu B, Zhang X Quant Imaging Med Surg. 2014; 4(1):50-6.

PMID: 24649435 PMC: 3947986. DOI: 10.3978/j.issn.2223-4292.2014.02.07.


Resonant Mode Reduction in Radiofrequency Volume Coils for Ultrahigh Field Magnetic Resonance Imaging.

Pang Y, Xie Z, Li Y, Xu D, Vigneron D, Zhang X Materials (Basel). 2011; 4(8):1333-1344.

PMID: 22081791 PMC: 3212035. DOI: 10.3390/ma4081333.


Comparison of volume, four- and eight-channel head coils using standard and parallel imaging.

Gizewski E, Maderwald S, Wanke I, Goehde S, Forsting M, Ladd M Eur Radiol. 2005; 15(8):1555-62.

PMID: 15856247 DOI: 10.1007/s00330-005-2730-0.


References
1.
Hayes C, Roemer P . Noise correlations in data simultaneously acquired from multiple surface coil arrays. Magn Reson Med. 1990; 16(2):181-91. DOI: 10.1002/mrm.1910160202. View

2.
Zoarski G, Mackey J, Anzai Y, Hanafee W, Melki P, Mulkern R . Head and neck: initial clinical experience with fast spin-echo MR imaging. Radiology. 1993; 188(2):323-7. DOI: 10.1148/radiology.188.2.8327673. View

3.
Fulbright R, Panush D, Sze G, Smith R, Constable R . MR of the head and neck: comparison of fast spin-echo and conventional spin-echo sequences. AJNR Am J Neuroradiol. 1994; 15(4):767-73. PMC: 8334213. View

4.
Hayes C, Hattes N, Roemer P . Volume imaging with MR phased arrays. Magn Reson Med. 1991; 18(2):309-19. DOI: 10.1002/mrm.1910180206. View

5.
ROSS M, Schomer D, Chappell P, Enzmann D . MR imaging of head and neck tumors: comparison of T1-weighted contrast-enhanced fat-suppressed images with conventional T2-weighted and fast spin-echo T2-weighted images. AJR Am J Roentgenol. 1994; 163(1):173-8. DOI: 10.2214/ajr.163.1.8010208. View