» Articles » PMID: 11724853

European Proficiency Testing Program for Molecular Detection and Quantitation of Hepatitis B Virus DNA

Overview
Specialty Microbiology
Date 2001 Nov 29
PMID 11724853
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

External quality control of hepatitis B virus (HBV) DNA detection remains an important issue. This study reports and compares the results obtained from two different proficiency panels for both the qualitative and quantitative assessment of HBV DNA. The panels were designed by the European Union Quality Control Concerted Action, prepared by Boston Biomedica, Inc., and distributed in May 1999 (panel 1) and February 2000 (panel 2). Each contained two negative samples and six positive samples with 10(3) to 10(7) copies/ml (panel 1) or 10(3) to 2 x 10(6) copies of HBV DNA per ml (panel 2). For panel 1, 42 laboratories submitted 20 qualitative (all in-house PCRs) and 37 quantitative (87% commercial assays) data sets. For panel 2, 51 laboratories submitted 25 qualitative (all in-house PCRs) and 47 quantitative (94% commercial assays) data sets. Five data sets (8.8%) in panel 1 and two data sets (2.8%) in panel 2 contained totals of six and two false-positives, respectively, corresponding to false-positive result rates of 5.3% for panel 1 and 1.4% for panel 2. The false-negative result rates of 10.5% for panel 1 and 17.4% for panel 2 were dependent on the detection levels of the assays employed as well as panel composition. In the qualitative analysis of all data sets, 47.4% (panel 1) and 51.4% (panel 2) had all samples correct. An adequate or better score (all correct or only the weak-positive sample missed) was obtained with 77.2% of the panel 1 samples and 68.1% of the panel 2 samples. In the quantitative analysis, 57.1% (panel 1) and 42.6% (panel 2) of the data sets achieved an adequate or better score (positive results within the acceptable range of the geometric mean +/- 0.5 log(10) of all positive results). These results demonstrate that while the qualitative performance of HBV detection has considerably improved compared to that of a previously published HBV proficiency study, the detection levels of many commercial quantitative assays are still too high to allow adequate quantitation of all relevant clinical samples.

Citing Articles

First external quality assurance program for bloodstream Real-Time PCR monitoring of treatment response in clinical trials of Chagas disease.

Ramirez J, Parrado R, Sulleiro E, De La Barra A, Rodriguez M, Villarroel S PLoS One. 2017; 12(11):e0188550.

PMID: 29176887 PMC: 5703561. DOI: 10.1371/journal.pone.0188550.


Ring test evaluation of the detection of influenza A virus in swine oral fluids by real-time reverse-transcription polymerase chain reaction and virus isolation.

Goodell C, Zhang J, Strait E, Harmon K, Patnayak D, Otterson T Can J Vet Res. 2016; 80(1):12-20.

PMID: 26733728 PMC: 4686030.


Development of magnetic capture hybridization and quantitative polymerase chain reaction for hepatitis B virus covalently closed circular DNA.

Guo Y, Sheng S, Nie B, Tu Z Hepat Mon. 2015; 15(1):e23729.

PMID: 25741372 PMC: 4344652. DOI: 10.5812/hepatmon.23729.


Multicenter external quality assessment program for PCR detection of Mycobacterium ulcerans in clinical and environmental specimens.

Eddyani M, Lavender C, De Rijk W, Bomans P, Fyfe J, de Jong B PLoS One. 2014; 9(2):e89407.

PMID: 24586755 PMC: 3931755. DOI: 10.1371/journal.pone.0089407.


Global proficiency study of human papillomavirus genotyping.

Eklund C, Zhou T, Dillner J J Clin Microbiol. 2010; 48(11):4147-55.

PMID: 20844222 PMC: 3020877. DOI: 10.1128/JCM.00918-10.


References
1.
Abe A, Inoue K, Tanaka T, Kato J, Kajiyama N, Kawaguchi R . Quantitation of hepatitis B virus genomic DNA by real-time detection PCR. J Clin Microbiol. 1999; 37(9):2899-903. PMC: 85408. DOI: 10.1128/JCM.37.9.2899-2903.1999. View

2.
Noborg U, Gusdal A, Pisa E, Hedrum A, Lindh M . Automated quantitative analysis of hepatitis B virus DNA by using the Cobas Amplicor HBV monitor test. J Clin Microbiol. 1999; 37(9):2793-7. PMC: 85382. DOI: 10.1128/JCM.37.9.2793-2797.1999. View

3.
Marin I, Poljak M, Seme K, Meglic-Volkar J, Maticic M, Lesnicar G . Comparative evaluation of semiautomated COBAS AMPLICOR hepatitis B virus (HBV) monitor test and manual microwell plate-based AMPLICOR HBV MONITOR test. J Clin Microbiol. 2001; 39(2):758-61. PMC: 87814. DOI: 10.1128/JCM.39.2.758-761.2001. View

4.
Van Vliet K, Muir P, Echevarria J, Klapper P, Cleator G, van Loon A . Multicenter proficiency testing of nucleic acid amplification methods for the detection of enteroviruses. J Clin Microbiol. 2001; 39(9):3390-2. PMC: 88355. DOI: 10.1128/JCM.39.9.3390-3392.2001. View

5.
Scotto J, Hadchouel M, Hery C, Yvart J, Tiollais P, Brechot C . Detection of hepatitis B virus DNA in serum by a simple spot hybridization technique: comparison with results for other viral markers. Hepatology. 1983; 3(3):279-84. DOI: 10.1002/hep.1840030301. View