» Articles » PMID: 11723087

Is One 60 Degrees Fundus Photograph Sufficient for Screening of Proliferative Diabetic Retinopathy?

Overview
Journal Diabetes Care
Specialty Endocrinology
Date 2001 Nov 28
PMID 11723087
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To compare one 60 degrees fundus photograph to seven field stereo fundus photographs in identifying proliferative diabetic retinopathy.

Research Design And Methods: A total of 44 eyes in 23 patients with moderate/severe nonproliferative diabetic retinopathy were included. Evaluation of each eye was based on one 60 degrees fundus photograph. Eyes were re-examined using seven field 30 degrees stereo fundus photographs according to the protocol of the Early Treatment Diabetic Retinopathy Study, and the photographs were examined independently by three ophthalmologists to identify retinal neovascular lesions. In addition, fluorescein angiography was performed in all patients to verify the presence of the lesions.

Results: In four eyes of three patients (11.1% of eyes) evaluated based on seven field stereo photographs, retinal neovascularization was found. This condition was not found on examination of 60 degrees fundus photographs.

Conclusions: Examination of one 60 degrees fundus photograph was found to be insufficient as a screening procedure in patients with moderate/severe nonproliferative diabetic retinopathy.

Citing Articles

One-field, two-field and five-field handheld retinal imaging compared with standard seven-field Early Treatment Diabetic Retinopathy Study photography for diabetic retinopathy screening.

Salongcay R, Jacoba C, Salva C, Rageh A, Aquino L, Saunar A Br J Ophthalmol. 2023; 108(5):735-741.

PMID: 37094836 PMC: 11137459. DOI: 10.1136/bjo-2022-321849.


The diagnostic accuracy of single- and five-field fundus photography in diabetic retinopathy screening by primary care physicians.

Srihatrai P, Hlowchitsieng T Indian J Ophthalmol. 2017; 66(1):94-97.

PMID: 29283131 PMC: 5778592. DOI: 10.4103/ijo.IJO_657_17.


Evaluation of diabetic retinopathy screening using a non-mydriatic retinal digital camera in primary care settings in south Israel.

Mizrachi Y, Knyazer B, Guigui S, Rosen S, Lifshitz T, Belfair N Int Ophthalmol. 2013; 34(4):831-7.

PMID: 24292883 DOI: 10.1007/s10792-013-9887-3.


The effect of glycaemic control on the quantitative characteristics of retinopathy lesions in patients with type 2 diabetes mellitus: 10-year follow-up study.

Kalesnykiene V, Sorri I, Voutilainen R, Uusitupa M, Niskanen L, Uusitalo H Graefes Arch Clin Exp Ophthalmol. 2008; 247(3):335-41.

PMID: 19043734 DOI: 10.1007/s00417-008-1001-6.


[Validation of the electronic mailing of retinographs of diabetic patients in order to detect retinopathy in primary care].

Molina Fernandez E, Valero Moll M, Gonzalez M, Calvo Lozano J, Sanchez Ramos J, Diaz Rodriguez E Aten Primaria. 2008; 40(3):119-23.

PMID: 18373923 PMC: 7713272. DOI: 10.1157/13116625.