Development and Application of a Sensitive High Performance Ion-exchange Chromatography Method for the Simultaneous Measurement of Dopamine, 5-hydroxytryptamine and Norepinephrine in Microdialysates from the Rat Brain

Overview
Specialty Neurology
Date 2001 Nov 22
PMID 11716948
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

A high performance liquid chromatography (HPLC) method based on cation exchange separation has been developed for the measurement of dopamine (DA), 5-hydroxytryptamine (5-HT) and norepinephrine (NE) in microdialysates. The separation conditions have been optimised for using electrochemical detection. All three bioamines were resolved in less than 22 min using isocratic conditions. The optimum oxidation potential for the three bioamines was found to be +0.4 V vs. in situ Ag/AgCl reference electrode. Linear regression analysis of HPLC-peak area as a function of concentrations in the range 1-50 ng x ml(-1) gave coefficients of correlation between 0.998 and 0.999. The limit of detection for DA, 5-HT and NE was found to be between 50 and 100 pg x ml(-1) with a signal to noise ratio of 3:1. The method has been applied to the simultaneous measurement of the three monoamines in microdialysates from the medial prefrontal cortex under basal conditions and following the administration of the antipsychotic drug clozapine (10 mg x kg(-1) s.c.).

Citing Articles

A review of applications of surface-enhanced raman spectroscopy laser for detection of biomaterials and a quick glance into its advances for COVID-19 investigations.

Eskandari V, Sahbafar H, Zeinalizad L, Hadi A ISSS J Micro Smart Syst. 2022; 11(2):363-382.

PMID: 35540110 PMC: 9070975. DOI: 10.1007/s41683-022-00103-x.


Redefining differential roles of MAO-A in dopamine degradation and MAO-B in tonic GABA synthesis.

Cho H, Kim S, Sim J, Yang S, An H, Nam M Exp Mol Med. 2021; 53(7):1148-1158.

PMID: 34244591 PMC: 8333267. DOI: 10.1038/s12276-021-00646-3.


Evaluation of electrochemical methods for tonic dopamine detection .

Rusheen A, Gee T, Jang D, Blaha C, Bennet K, Lee K Trends Analyt Chem. 2021; 132.

PMID: 33597790 PMC: 7885180. DOI: 10.1016/j.trac.2020.116049.


Analysis of Catecholamines and Pterins in Inborn Errors of Monoamine Neurotransmitter Metabolism-From Past to Future.

Jung-Klawitter S, Hubschmann O Cells. 2019; 8(8).

PMID: 31405045 PMC: 6721669. DOI: 10.3390/cells8080867.


Raman Computational and Experimental Studies of Dopamine Detection.

Ciubuc J, Bennet K, Qiu C, Alonzo M, Durrer W, Manciu F Biosensors (Basel). 2017; 7(4).

PMID: 28956820 PMC: 5746766. DOI: 10.3390/bios7040043.