» Articles » PMID: 11716046

Twenty-one-gauge Needles Provide More Cellular Samples Than Twenty-five-gauge Needles in Fine-needle Aspiration Biopsy of the Thyroid but May Not Provide Increased Diagnostic Accuracy

Overview
Journal Thyroid
Date 2001 Nov 22
PMID 11716046
Citations 15
Authors
Affiliations
Soon will be listed here.
Abstract

The technique of fine-needle aspiration (FNA) biopsy of the thyroid is important to evaluate malignancy in thyroid nodules. Eighty-five percent of thyroid FNA procedures lead to sufficient cellular material for diagnosis. With more cells aspirated, the chance of sufficiency for diagnosis increases. Large-bore needles lead to more cellular material being aspirated but bloodier specimens that may interfere with cytologic interpretation. Small-bore needles may result in too few cells for diagnosis. We conducted a randomized prospective study contrasting 21-gauge and 25-gauge needles in the evaluation of 50 consecutively enrolled nodules at our institution. In our investigation, 21-gauge needles more frequently provided superior biopsy specimens (50%) than did 25-gauge needles (18%). In the remaining specimens (32%), the 21-gauge and 25-gauge needles provided similar cellular material. The rate of sufficient samples was the same. We conclude that use of 21-gauge needles results in more cellular specimens but may not result in increased diagnostic accuracy.

Citing Articles

A Comprehensive Assessment of the Harms of Fine-Needle Aspiration Biopsy for Thyroid Nodules: A Systematic Review.

Park J, Choi W, Hong A, Yoon J, Kim H, Kang H Endocrinol Metab (Seoul). 2023; 38(1):104-116.

PMID: 36891657 PMC: 10008658. DOI: 10.3803/EnM.2023.1669.


Ultrasound-Guided Fine Needle Aspiration of Deep Thyroid Nodule: Is There a Correlation between the Nodule's Depth and Nondiagnostic Results?.

Asakly M, Farhat R, El Khatib N, Khater A, Safia A, Karam M J Thyroid Res. 2022; 2022:8212636.

PMID: 36071949 PMC: 9444405. DOI: 10.1155/2022/8212636.


A Rare Complication of Fine-Needle Aspiration of Neck Structures.

Qadadha Y, Nanda N, Ennis C, McCulloch T Case Rep Otolaryngol. 2021; 2021:8944119.

PMID: 34956684 PMC: 8695029. DOI: 10.1155/2021/8944119.


Comparison of Ultrasound-Guided Fine-Needle Cytology Quality in Thyroid Nodules with 22-, 23-, and 25-Gauge Needles.

Dong Y, Gao L, Sui Y, Mao M, Zhan W, Zhou J Anal Cell Pathol (Amst). 2021; 2021:5544921.

PMID: 34211823 PMC: 8205598. DOI: 10.1155/2021/5544921.


Effect of needle gauge on thyroid FNA diagnostic rate.

Saraph S, Cohen H, Ronen O Endocrine. 2021; 74(3):625-631.

PMID: 34146249 DOI: 10.1007/s12020-021-02797-9.