Electropositive Filter Membrane As an Alternative for the Elimination of PCR Inhibitors from Sewage and Water Samples

Overview
Date 2001 Sep 26
PMID 11571164
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

PCR is the best method for the detection of enteric viruses present at low concentrations in environmental samples. However, some organic and inorganic compounds present in these samples can interfere in the reaction. Many of these substances are cytotoxic, too. The ZP60S filter membranes used in addition to fluorpentane treatment are quite efficient for virus concentration and simultaneous elimination of cytotoxicity from environmental samples. In this study, both procedures were used to promote the elimination of reverse transcriptase PCR (RT-PCR) inhibitors from sewage and sewage-polluted creek water. Samples were subjected separately to each of the following procedures: filtration through electropositive filter membranes (ZP60S), organic extraction with Vertrel XF, and filtration through ZP60S followed by organic extraction. Afterwards, aliquots were experimentally inoculated with rotavirus SA-11 RNA and subjected to RT-seminested PCR for amplification of the VP7 gene. Results showed that the ZP60S membranes efficiently eliminated the RT-PCR inhibitors from water samples. The sample processing method was also applied to 31 in natural sewage and creek water samples for detection of naturally occurring rotavirus. A duplex seminested PCR was used for the quick detection of couples of the four rotavirus genotypes (G1 to G4). Eight samples (25.8%) were positive, and rotavirus sequences were not detected in 23 (74.2%). Results were confirmed by direct immunoperoxidase method. In summary, the use of electropositive filter membrane is appropriate for the elimination of substances that can interfere with RT-PCR, obviating additional sample purification methods.

Citing Articles

Evaluation of Well Designs to Improve Access to Safe and Clean Water in Rural Tanzania.

Kilungo A, Powers L, Arnold N, Whelan K, Paterson K, Young D Int J Environ Res Public Health. 2018; 15(1).

PMID: 29300305 PMC: 5800163. DOI: 10.3390/ijerph15010064.


Identification of circo-like virus-Brazil genomic sequences in raw sewage from the metropolitan area of São Paulo: evidence of circulation two and three years after the first detection.

Castrignano S, Nagasse-Sugahara T, Garrafa P, Monezi T, Barrella K, Mehnert D Mem Inst Oswaldo Cruz. 2017; 112(3):175-181.

PMID: 28146157 PMC: 5319365. DOI: 10.1590/0074-02760160312.


GenSeed-HMM: A Tool for Progressive Assembly Using Profile HMMs as Seeds and its Application in Alpavirinae Viral Discovery from Metagenomic Data.

Alves J, de Oliveira A, Sandberg T, Moreno-Gallego J, de Toledo M, de Moura E Front Microbiol. 2016; 7:269.

PMID: 26973638 PMC: 4777721. DOI: 10.3389/fmicb.2016.00269.


Longitudinal study on occurrence of adenoviruses and hepatitis A virus in raw domestic sewage in the city of Limeira, SÃo Paulo.

Barrella K, Garrafa P, Monezi T, Harsi C, Salvi C, Violante P Braz J Microbiol. 2013; 40(1):102-7.

PMID: 24031326 PMC: 3768521. DOI: 10.1590/S1517-838220090001000017.


Phylodynamics and movement of Phycodnaviruses among aquatic environments.

Gimenes M, Zanotto P, Suttle C, da Cunha H, Mehnert D ISME J. 2011; 6(2):237-47.

PMID: 21796218 PMC: 3260511. DOI: 10.1038/ismej.2011.93.


References
1.
Abbaszadegan M, Huber M, Gerba C, Pepper I . Detection of enteroviruses in groundwater with the polymerase chain reaction. Appl Environ Microbiol. 1993; 59(5):1318-24. PMC: 182083. DOI: 10.1128/aem.59.5.1318-1324.1993. View

2.
Schwab K, de Leon R, Sobsey M . Concentration and purification of beef extract mock eluates from water samples for the detection of enteroviruses, hepatitis A virus, and Norwalk virus by reverse transcription-PCR. Appl Environ Microbiol. 1995; 61(2):531-7. PMC: 167314. DOI: 10.1128/aem.61.2.531-537.1995. View

3.
Estes M, Palmer E, Obijeski J . Rotaviruses: a review. Curr Top Microbiol Immunol. 1983; 105:123-84. DOI: 10.1007/978-3-642-69159-1_3. View

4.
Steinmann J . Detection of rotavirus in sewage. Appl Environ Microbiol. 1981; 41(4):1043-5. PMC: 243854. DOI: 10.1128/aem.41.4.1043-1045.1981. View

5.
Sobsey M, Jones B . Concentration of poliovirus from tap water using positively charged microporous filters. Appl Environ Microbiol. 1979; 37(3):588-95. PMC: 243259. DOI: 10.1128/aem.37.3.588-595.1979. View