» Articles » PMID: 11535472

Anterior Capsule Opacification: Correlation of Pathologic Findings with Clinical Sequelae

Overview
Journal Ophthalmology
Publisher Elsevier
Specialty Ophthalmology
Date 2001 Sep 6
PMID 11535472
Citations 27
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To evaluate the degree of anterior capsule opacification (ACO) in human eyes obtained postmortem containing various rigid and foldable posterior chamber intraocular lens (PC-IOL) designs and compare the findings with clinical sequelae of capsular shrinkage.

Design: Comparative autopsy tissue study with clinicopathologic correlations.

Materials: Three hundred formalin-fixed human eyes containing the following PC-IOL styles were analyzed: (1) one-piece polymethyl methacrylate (PMMA) optic-PMMA haptic (n = 50), one-piece silicone-plate IOL, with large (2) or small (3) fixation holes (n = 35), (4) three-piece PMMA optic-Prolene haptic (n = 50), (5) three-piece acrylic optic-PMMA haptic (n = 55), three-piece silicone optic with PMMA (6) or polyimide (7) haptics (n = 30), and (8) three-piece silicone optic-Prolene haptic (n = 80) lenses.

Testing: The eyes were sectioned in the equatorial plane for gross examination of the capsular bag from a posterior view. The cornea and iris were then excised for evaluation from an anterior view.

Main Outcome Measures: ACO was scored in each eye from 0 to IV, according to the degree/area of capsule opacification. Capsulorrhexis size and IOL decentration were measured with calipers.

Results: The overall differences among the IOL groups regarding the three parameters were significant (ACO score: P < 0.001; capsulorrhexis diameter: P = 0.036; IOL decentration: P = 0.012). Mean ACO scores were highest with the large- and small-hole one-piece silicone-plate lenses (2.543 +/- 0.950) and lowest with the three-piece acrylic optic-PMMA haptic lenses (0.600 +/- 0.710). Of 10 cases of capsulorrhexis phimosis observed in the study, 7 cases were associated with three-piece silicone optic-Prolene haptic lenses, which also presented the highest mean decentration (0.375 +/- 0.601 mm).

Conclusions: Our results confirm previous histopathologic observations that the rate of ACO is the lowest with acrylic lenses and higher with plate-haptic silicone IOLs. Nevertheless, clinical sequelae of capsular shrinkage are also very important with three-piece silicone optic-Prolene haptic designs. Thus, IOL material and design are significant factors in the development of ACO, but they ultimately also influence the clinical presentation of capsular shrinkage.

Citing Articles

Ocular characteristics and outcomes of phacoemulsification in patients with cataract after renal transplantation.

Chen Y, Yang P, Li W, Huo L Int Ophthalmol. 2024; 44(1):255.

PMID: 38909160 DOI: 10.1007/s10792-024-03161-2.


Effects of intraocular lens anterior edge design on anterior capsule morphology changes following femtosecond laser-assisted capsulotomy.

Liu Q, Zhang S, Wang X, Liu J, Zhou G, Yuan X BMC Ophthalmol. 2022; 22(1):515.

PMID: 36581925 PMC: 9801536. DOI: 10.1186/s12886-022-02751-x.


Complete Occlusion of Anterior Capsular Opening in Patient Operated for Cataract With Penetrating Keratoplasty.

Joshi R, Wadekar P Cureus. 2022; 14(5):e25178.

PMID: 35746988 PMC: 9209404. DOI: 10.7759/cureus.25178.


Histopathological analysis of residual lens cells in capsular opacities after cataract surgery using objective software.

Mastromonaco C, Balazsi M, Coblentz J, Dias A, Zoroquiain P, Burnier Jr M Indian J Ophthalmol. 2022; 70(5):1617-1625.

PMID: 35502038 PMC: 9332936. DOI: 10.4103/ijo.IJO_291_21.


Weight of Different Intraocular Lenses: Evaluation of Toricity, Focality, Design, and Material.

Lopez-Vazquez A, Contreras I, Martin-Prieto S, Lopez-Castro A J Ophthalmol. 2021; 2021:6686700.

PMID: 33968444 PMC: 8081614. DOI: 10.1155/2021/6686700.