Approaches to Establishing Reference Levels in Interventional Radiology

Overview
Date 2001 Aug 8
PMID 11487815
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Reference levels in radiodiagnostics are a requirement stated by the Council Directive 97/43/EURATOM. Reference levels are also relevant for interventional procedures, in accordance with this Directive, which claims special attention to quality assurance programmes, including quality control and patient dose evaluations for special practices such as interventional radiology, to assess the convenience of corrective action depending on the measured doses. The present paper addresses a method of establishing reference levels in interventional radiology, in the framework of optimisation, discussing the ways of putting forward values with a degree of tolerance, to allow for procedure complexity, depending on patient pathology. The need for several estimators used together, namely fluoroscopy time, total number of images per procedure and dose-area product, is also emphasised, proposing a further skin dose estimate in case of risk of deterministic effects. Finally, a brief summary of principles is given for the correct management of reference levels in interventional radiology.

Citing Articles

Radiation dose reduction during venous access port implantation: the importance of upgrading equipment and radiation-protection training.

Vallot D, Cavillon A, Lusque A, Izard P, Salvignol G, Delpuech B Ir J Med Sci. 2024; 193(3):1461-1466.

PMID: 38349509 DOI: 10.1007/s11845-024-03623-7.


Patient dose in interventional radiology: a multicentre study of the most frequent procedures in France.

Etard C, Bigand E, Salvat C, Vidal V, Beregi J, Hornbeck A Eur Radiol. 2017; 27(10):4281-4290.

PMID: 28289939 DOI: 10.1007/s00330-017-4780-5.


Reference levels and patient doses in interventional cardiology procedures in Greece.

Simantirakis G, Koukorava C, Kalathaki M, Pafilis C, Kaisas I, Economides S Eur Radiol. 2013; 23(8):2324-32.

PMID: 23559142 DOI: 10.1007/s00330-013-2813-2.


Patient radiation dose audits for fluoroscopically guided interventional procedures.

Baiter S, Rosenstein M, Miller D, Schueler B, Spelic D Med Phys. 2011; 38(3):1611-8.

PMID: 21520873 PMC: 3064683. DOI: 10.1118/1.3557868.


Reference levels for patient radiation doses in interventional radiology: proposed initial values for U.S. practice.

Miller D, Kwon D, Bonavia G Radiology. 2009; 253(3):753-64.

PMID: 19789226 PMC: 2786193. DOI: 10.1148/radiol.2533090354.