» Articles » PMID: 11486305

New Developments in Diagnosis and Treatment of Infection in Orthopedic Implants

Overview
Journal Clin Infect Dis
Date 2001 Aug 7
PMID 11486305
Citations 96
Authors
Affiliations
Soon will be listed here.
Abstract

Orthopedic implants have revolutionized treatment of bone fractures and noninfectious joint arthritis. Today, the risk for orthopedic device-related infection (ODRI) is <1%-2%. However, the absolute number of patients with infection continuously increases as the number of patients requiring such implants grows. Treatment of ODRIs most frequently includes long-term antimicrobial treatment and removal of the implant. Recent evidence from observational trials and 1 randomized clinical trial indicate that a subset of patients can be successfully treated with retention of the implant. Patients eligible for such a treatment must meet the following criteria: acute infection defined as signs and symptoms lasting <14-28 days, an unambiguous diagnosis based on histopathology and microbiology, a stable implant, and susceptibility of the microorganism to an effective orally available antimicrobial agent.

Citing Articles

Biofilm morphology and antibiotic susceptibility of methicillin-resistant (MRSA) on poly-D,L-lactide--poly(ethylene glycol) (PDLLA-PEG) coated titanium.

Turner A, Zermeno-Perez D, Mysior M, Giraldo-Osorno P, Garcia B, OGorman E Biofilm. 2025; 8():100228.

PMID: 39830519 PMC: 11740804. DOI: 10.1016/j.bioflm.2024.100228.


Photoacoustic imaging of a cyanine dye targeting bacterial infection.

Swann R, Hernandez-Valdes D, Silva L, Marfatia Y, El-Zaria M, Genady A Sci Rep. 2024; 14(1):18322.

PMID: 39112643 PMC: 11306741. DOI: 10.1038/s41598-024-69148-2.


Enhanced antibiofilm potential of low-intensity pulsed ultrasound combined with 0.35% povidone-iodine in a rat model of periprosthetic joint infection.

Wang T, Yang C, Li G, Wang Y, Ji B, Chen Y Bone Joint Res. 2024; 13(7):332-341.

PMID: 38964744 PMC: 11223899. DOI: 10.1302/2046-3758.137.BJR-2023-0339.R1.


pH-Triggered Controlled Release of Chlorhexidine Using Chitosan-Coated Titanium Silica Composite for Dental Infection Prevention.

Srivastava M, Kamarudin N, Aktan M, Zheng K, Zayed N, Yongabi D Pharmaceutics. 2024; 16(3).

PMID: 38543271 PMC: 10974051. DOI: 10.3390/pharmaceutics16030377.


Antifouling Behavior of Copper-Modified Titania Nanotube Surfaces.

Savargaonkar A, Munshi A, Soares P, Popat K J Funct Biomater. 2023; 14(8).