» Articles » PMID: 11451128

Does Modularity Affect Clinical Success? A Comparison with a Minimum 10-year Followup

Overview
Publisher Wolters Kluwer
Specialty Orthopedics
Date 2001 Jul 14
PMID 11451128
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

A comparison of the clinical and radiographic results of patients with metal-backed monoblock Insall-Burstein I and modular Insall-Burstein II Posterior Stabilized Knee Prostheses was done. The minimum followup was 10 years. The clinical results were comparable with a similar average Hospital for Special Surgery knee score of 85 and 84 points, respectively. Likewise, the Knee Society Knee and Functional Scores showed no statistical difference. Radiographically, the incidence of minor radiolucent lines was 11% for the Insall-Burstein I prostheses and 29% for the Insall-Burstein II prostheses, but their presence was of no clinical significance. There was no clinical or radiographic evidence of tibial component loosening with either prosthetic design and there were no revisions for polyethylene wear or osteolysis in either cohort of patients.

Citing Articles

Mid term results of LCS knee: The Indian experience.

Maniar R, Singhi T, Gangaraju B, Patil A, Maniar P Indian J Orthop. 2013; 47(1):57-62.

PMID: 23532673 PMC: 3601235. DOI: 10.4103/0019-5413.106903.


The Columbus Knee System: 4-Year Results of a New Deep Flexion Design Compared to the NexGen Full Flex Implant.

Goebel D, Schultz W Arthritis. 2012; 2012:213817.

PMID: 22496976 PMC: 3310259. DOI: 10.1155/2012/213817.