» Articles » PMID: 11391289

Reference Values for Echocardiographic Measurements in Urban and Rural Populations of Differing Ethnicity: the Strong Heart Study

Overview
Specialty Radiology
Date 2001 Jun 8
PMID 11391289
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

Discrepancies in reported reference values for left ventricular (LV) dimensions and mass may be due to imaging errors with early echocardiographic methods or effects of subject characteristics and inclusion criteria. To determine whether contemporary echocardiographic methods provide stable normal limits for left ventricular measurements in different populations, M-mode/2-dimensional echocardiography was applied in 176 American Indian participants in the Strong Heart Study and 237 New York City residents who were clinically normal. No consistent difference in any measure of LV size or function existed between populations. Upper normal limits (98th percentile) for LV mass were 96 g/m(2) in women and 116 g/m(2) in men and 3.27 cm/m for LV chamber diameter normalized for height. Thus contemporary M-mode/2D echocardiography provides reference ranges for LV measurements that approximate necropsy measurements and have acceptable stability in apparently normal white, African-American/Caribbean, and American Indian populations.

Citing Articles

Echocardiographic Measurements in Normal Healthy Adult Population of North India.

Rashid A, Shah A, Rather H, Rasool V, Hafeez I, Ajaz S Cureus. 2023; 15(10):e47449.

PMID: 38022041 PMC: 10660080. DOI: 10.7759/cureus.47449.


Prognostic value of left atrial size in hypertensive African Americans undergoing stress echocardiography.

Khemka A, Sutter D, Habhab M, Thomaides A, Hornsby K, Feigenbaum H World J Cardiol. 2022; 13(12):733-744.

PMID: 35070115 PMC: 8716971. DOI: 10.4330/wjc.v13.i12.733.


A study on normal reference values of echocardiographic chamber dimensions in young eastern Indian adults.

Mukherjee A, Halder S, Nandi S, Mandal M, Khanra D, Biswas K Indian Heart J. 2021; 73(1):77-84.

PMID: 33714414 PMC: 7961241. DOI: 10.1016/j.ihj.2020.12.010.


Normal echocardiographic measurements in a Turkish population: The Healthy Heart ECHO-TR Trial.

Safak O, Gursoy O, Karakoyun S, Cagdas M, Asarcikli L, Avci Demir F Anatol J Cardiol. 2019; 22(5):262-270.

PMID: 31674928 PMC: 6955065. DOI: 10.14744/AnatolJCardiol.2019.45845.


Normative reference ranges for echocardiographic chamber dimensions in a healthy Central European population: results from the Czech post-MONICA survey.

Marek J, Lubanda J, Cifkova R, Kuchynka P, Golan L, Nemcek E Cardiovasc Ultrasound. 2019; 17(1):22.

PMID: 31666068 PMC: 6822480. DOI: 10.1186/s12947-019-0172-0.