» Articles » PMID: 11382425

Dall-Miles Cable and Plate Fixation for the Treatment of Peri-prosthetic Femoral Fractures-analysis of Results in 13 Cases

Overview
Journal Injury
Publisher Elsevier
Specialty Emergency Medicine
Date 2001 May 31
PMID 11382425
Citations 15
Authors
Affiliations
Soon will be listed here.
Abstract

We present a retrospective review of 13 patients with periprosthetic femoral fractures treated with the Dall-Miles cable and plate fixation system between 1995 and 1999. Of these, 12 fractures were in relation to hip arthroplasty and one was proximal to the femoral component of a total knee replacement. Mean age at presentation was 77 years (range 66-87) with the male female ratio of 6:7. All patients were followed up until there was evidence of clinical and radiological union. The average follow-up period was 6.5 months (range 2.5-24). We achieved satisfactory results in ten patients with average time to union of 4.4 months. The results were unsatisfactory in three patients who required further revision procedures due to failure of fixation or non-union. Internal fixation of the fracture with the loose femoral component left in-situ led to failure of union in one patient. Varus mal-alignment of the femoral component to the shaft of more than 6 degrees was associated with unsatisfactory outcome in two patients. The Dall-Miles cable and plate system is a useful method of internal fixation for majority of periprosthetic femoral fractures. This method may not be suitable if the femoral component is loose or if it is in varus angulation of more than 6 degrees to the shaft of the femur.

Citing Articles

Surgical outcomes of cable plate fixation in treatment of Vancouver type B1 and type C periprosthetic femoral fractures: a retrospective case series.

Sen C, Kizilkurt T, Demirel M, Yildirim A, Saglam Y, Ozturk I Acta Orthop Traumatol Turc. 2024; 58(4):235-243.

PMID: 39323230 PMC: 11448770. DOI: 10.5152/j.aott.2024.23124.


Treatment of Bifocal Periprosthetic Fractures above and below a Knee after Tumor using Spanning Ilizarov Device: A Case Report.

Lerner A, Jakusonoka R, Jumtins A, Rothem D J Orthop Case Rep. 2023; 13(9):33-37.

PMID: 37753117 PMC: 10519321. DOI: 10.13107/jocr.2023.v13.i09.3866.


Osteosynthesis and outcomes of traumatic periprosthetic femoral fractures after total hip arthroplasty.

Taha A, Elzaher E, ElGanzoury I, Ashoub M, Khairy A Arthroplasty. 2022; 3(1):31.

PMID: 35236470 PMC: 8796630. DOI: 10.1186/s42836-021-00089-1.


Early experience with the use of trochanteric reattachment plate for the treatment of Vancouver type B 1 periprosthetic hip fractures.

Londhe S, Churhe S, Omprakash Agrawal P, Shirishkar R, Malcolm Pestonji J, Antao N J Clin Orthop Trauma. 2022; 23:101644.

PMID: 35070683 PMC: 8758910. DOI: 10.1016/j.jcot.2021.101644.


Trochanteric osteotomy in revision total hip arthroplasty.

Sundaram K, Siddiqi A, Kamath A, Higuera-Rueda C EFORT Open Rev. 2020; 5(8):477-485.

PMID: 32953133 PMC: 7484712. DOI: 10.1302/2058-5241.5.190063.