Abstract

Up-Converting Phosphor Technology (UPT) is based on lanthanide-containing, submicrometer-sized, ceramic particles that can absorb infrared light and emit visible light. Biological matrices do not up-convert; hence, there is no contribution to test background from sample autofluorescence. Up-converting phosphors do not photobleach and are inert to common assay interferants such as hemoglobin. A reader called UPlink has been developed to interrogate lateral flow test strips that utilize UPT labels. The reader contains a miniaturized, 1-W, infrared laser with peak emission at 980 nm. Preliminary assays that use up-converting phosphor labels, including tests for a drugs of abuse panel and Escherichia coli O157:H7, have been developed. In a "sandwich" assay format, 10(3) org/mL E. coli O157:H7 organisms were detectable in a negative control background of 10(9) other organisms per milliliter of culture medium. Coefficients of variation in concentrations tested from 0 to 10(7) org/mL were all < or =10%. In a competitive inhibition assay format, a multiplexed test simultaneously detected amphetamine, methamphetamine, phencyclidine, and opiates in saliva. For all assays, the percent displacement at 10 ng/mL was > or =40% demonstrating performance comparable with lab-based, commercially available EIAs. All assays were complete in 10 min. The development of rapid tests using UPT creates new applications for on-site testing with sensitivity not available using other label technologies.

Citing Articles

Rapid test for Mycobacterium leprae infection: a practical tool for leprosy.

Pierneef L, van Hooij A, de Jong D, Wassenaar G, Verhard E, Tjon Kon Fat E Infect Dis Poverty. 2024; 13(1):88.

PMID: 39617937 PMC: 11610287. DOI: 10.1186/s40249-024-01262-9.


Artificial intelligence reinforced upconversion nanoparticle-based lateral flow assay via transfer learning.

Wang W, Chen K, Ma X, Guo J Fundam Res. 2024; 3(4):544-556.

PMID: 38933552 PMC: 11197505. DOI: 10.1016/j.fmre.2022.03.025.


Detection of Cannabinoids in Oral Fluid Specimens as the Preferred Biological Matrix for a Point-of-Care Biosensor Diagnostic Device.

Trif C, Harpaz D, Eltzov E, Parcharoen Y, Pechyen C, Marks R Biosensors (Basel). 2024; 14(3).

PMID: 38534233 PMC: 10968443. DOI: 10.3390/bios14030126.


Microfluidic Paper-based Device for Medicinal Diagnosis.

Lomae A, Preechakasedkit P, Teekayupak K, Panraksa Y, Yukird J, Chailapakul O Curr Top Med Chem. 2022; 22(27):2282-2313.

PMID: 36330618 DOI: 10.2174/1568026623666221103103211.


Lateral Flow Immunoassay Reader Technologies for Quantitative Point-of-Care Testing.

Park J Sensors (Basel). 2022; 22(19).