» Articles » PMID: 11336534

Direct Measurement of Erythrocyte Deformability in Diabetes Mellitus with a Transparent Microchannel Capillary Model and High-speed Video Camera System

Overview
Journal Microvasc Res
Date 2001 May 5
PMID 11336534
Citations 48
Authors
Affiliations
Soon will be listed here.
Abstract

To measure erythrocyte deformability in vitro, we made transparent microchannels on a crystal substrate as a capillary model. We observed axisymmetrically deformed erythrocytes and defined a deformation index directly from individual flowing erythrocytes. By appropriate choice of channel width and erythrocyte velocity, we could observe erythrocytes deforming to a parachute-like shape similar to that occurring in capillaries. The flowing erythrocytes magnified 200-fold through microscopy were recorded with an image-intensified high-speed video camera system. The sensitivity of deformability measurement was confirmed by comparing the deformation index in healthy controls with erythrocytes whose membranes were hardened by glutaraldehyde. We confirmed that the crystal microchannel system is a valuable tool for erythrocyte deformability measurement. Microangiopathy is a characteristic complication of diabetes mellitus. A decrease in erythrocyte deformability may be part of the cause of this complication. In order to identify the difference in erythrocyte deformability between control and diabetic erythrocytes, we measured erythrocyte deformability using transparent crystal microchannels and a high-speed video camera system. The deformability of diabetic erythrocytes was indeed measurably lower than that of erythrocytes in healthy controls. This result suggests that impaired deformability in diabetic erythrocytes can cause altered viscosity and increase the shear stress on the microvessel wall.

Citing Articles

Confinement effect on the microcapillary flow and shape of red blood cells.

Nouaman M, Darras A, Wagner C, Recktenwald S Biomicrofluidics. 2024; 18(2):024104.

PMID: 38577010 PMC: 10994673. DOI: 10.1063/5.0197208.


Partitioning of dense RBC suspensions in single microfluidic bifurcations: role of cell deformability and bifurcation angle.

Stathoulopoulos A, Passos A, Kaliviotis E, Balabani S Sci Rep. 2024; 14(1):535.

PMID: 38177195 PMC: 10767057. DOI: 10.1038/s41598-023-49849-w.


New erythrocyte parameters derived from the Coulter principle relate with red blood cell properties-A pilot study in diabetes mellitus.

Bourguignon C, Ansel C, Gineys J, Schuldiner S, Isebe D, Geitner M PLoS One. 2023; 18(10):e0293356.

PMID: 37883361 PMC: 10602249. DOI: 10.1371/journal.pone.0293356.


Morphometric and Nanomechanical Screening of Peripheral Blood Cells with Atomic Force Microscopy for Label-Free Assessment of Alzheimer's Disease, Parkinson's Disease, and Amyotrophic Lateral Sclerosis.

Taneva S, Todinova S, Andreeva T Int J Mol Sci. 2023; 24(18).

PMID: 37762599 PMC: 10531602. DOI: 10.3390/ijms241814296.


Interdependence of Rheological and Biochemical Parameters of Blood in a Group of Patients with Clinically Silent Multifocal Vascular Cerebral Lesions.

Marcinkowska-Gapinska A, Siemieniak I, Kawalkiewicz W, Stieler O, Hojan-Jezierska D, Kubisz L Biomedicines. 2023; 11(7).

PMID: 37509703 PMC: 10376949. DOI: 10.3390/biomedicines11072063.