Fractional Flow Reserve, Absolute and Relative Coronary Blood Flow Velocity Reserve in Relation to the Results of Technetium-99m Sestamibi Single-photon Emission Computed Tomography in Patients with Two-vessel Coronary Artery Disease

Overview
Date 2001 Apr 13
PMID 11300441
Citations 21
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: We sought to perform a direct comparison between perfusion scintigraphic results and intracoronary-derived hemodynamic variables (fractional flow reserve [FFR]; absolute and relative coronary flow velocity reserve [CFVR and rCFVR, respectively]) in patients with two-vessel disease.

Background: There is limited information on the diagnostic accuracy of intracoronary-derived variables (CFVR, FFR and rCFVR) in patients with multivessel disease.

Methods: Dipyridamole technetium-99m sestamibi (MIBI) single-photon emission computed tomography (SPECT) was performed in 127 patients. The presence of reversible perfusion defects in the region of interest was determined. Within one week, angiography was performed; CFVR, rCFVR and FFR were determined in 161 coronary lesions after intracoronary administration of adenosine. The predictive value for the presence of reversible perfusion defects on MIBI SPECT of CFVR, rCFVR and FFR was evaluated by the area under the curve (AUC) of the receiver operating characteristics curves.

Results: The mean percentage diameter stenosis was 57% (range 35% to 85%), as measured by quantitative coronary angiography. Using per-patient analysis, the AUCs for CFVR (0.70 +/- 0.052), rCFVR (0.72 +/- 0.051) and FFR (0.76 +/- 0.050) were not significantly different (p = NS). The percentages of agreement with the results of MIBI SPECT were 76%, 78% and 77% for CFVR, rCFVR and FFR, respectively. Per-lesion analysis, using all 161 measured lesions, yielded similar results.

Conclusions: The diagnostic accuracy of three intracoronary-derived hemodynamic variables, as compared with the results of perfusion scintigraphy, is similar in patients with two-vessel coronary artery disease. Cut-offvalues of 2.0 for CFVR, 0.65 for rCFVR and 0.75 for FFR can be used for clinical decision-making in this patient cohort. Discordant results were obtained in 23% of the cases that require prospective evaluation for appropriate patient management.

Citing Articles

Diagnostic performance of CT-derived resting distal to aortic pressure ratio (resting Pd/Pa) CT-derived fractional flow reserve (CT-FFR) in coronary lesion severity assessment.

Li Q, Zhang Y, Wang C, Dong S, Mao Y, Tang Y Ann Transl Med. 2021; 9(17):1390.

PMID: 34733942 PMC: 8506529. DOI: 10.21037/atm-21-4325.


Invasive coronary physiology: a Dutch tradition.

van de Hoef T, de Waard G, Meuwissen M, Voskuil M, Chamuleau S, van Royen N Neth Heart J. 2020; 28(Suppl 1):99-107.

PMID: 32780339 PMC: 7419414. DOI: 10.1007/s12471-020-01461-7.


Objective Identification of Intermediate Lesions Inducing Myocardial Ischemia Using Sequential Intracoronary Pressure and Flow Measurements.

Stegehuis V, Wijntjens G, Nijjer S, de Waard G, van de Hoef T, Sen S J Am Heart Assoc. 2020; 9(13):e015559.

PMID: 32573324 PMC: 7670511. DOI: 10.1161/JAHA.119.015559.


Impact of clinical and haemodynamic factors on coronary flow reserve and invasive coronary flow capacity in non-obstructed coronary arteries: a patient-level pooled analysis of the DEBATE and ILIAS studies.

Stegehuis V, Wijntjens G, Bax M, Meuwissen M, Chamuleau S, Voskuil M EuroIntervention. 2020; 16(18):e1503-e1510.

PMID: 31951205 PMC: 9724860. DOI: 10.4244/EIJ-D-19-00774.


Fractional Flow Reserve or Coronary Flow Reserve for the Assessment of Myocardial Perfusion : Implications of FFR as an Imperfect Reference Standard for Myocardial Ischemia.

Stegehuis V, Wijntjens G, Piek J, van de Hoef T Curr Cardiol Rep. 2018; 20(9):77.

PMID: 30046914 PMC: 6061210. DOI: 10.1007/s11886-018-1017-4.