Overlaying Ultrasonographic Images on Direct Vision

Overview
Date 2001 Mar 29
PMID 11270527
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

The objective of this technical advance is to permit in situ visualization of ultrasonographic images so that direct hand-eye coordination can be used during invasive procedures. A method is presented that merges the visual outer surface of a patient with a simultaneous ultrasonographic scan of the patient's interior. The method combines a flat-panel monitor with a half-silvered mirror such that the image on the monitor is reflected precisely at the proper location within the patient. The ultrasonographic image is superimposed in real time on the patient, merging with the operator's hands and any invasive tools in the field of view. Instead of looking away from the patient at an ultrasonographic monitor, the operator sees through skin and underlying tissue as if it were translucent. Two working prototypes have been constructed, demonstrating independence of viewer location and requiring no special apparatus to be worn by the operator. This method could enable needles and scalpels to be manipulated with direct hand-eye coordination under ultrasonographic guidance. Invasive tools would be visible up to where they enter the skin, permitting natural visual extrapolation into the ultrasonographic slice. Biopsy needles would no longer be restricted to lie in the plane of the ultrasonographic scan but could instead intersect it. These advances could lead to increased safety, ease, and reliability in certain invasive procedures.

Citing Articles

Integrating images from a moveable tracked display of three-dimensional data.

Shukla G, Klatzky R, Wu B, Wang B, Galeotti J, Chapmann B Cogn Res Princ Implic. 2017; 2(1):34.

PMID: 28890919 PMC: 5569642. DOI: 10.1186/s41235-017-0069-0.


Instrument-mounted displays for reducing cognitive load during surgical navigation.

Herrlich M, Tavakol P, Black D, Wenig D, Rieder C, Malaka R Int J Comput Assist Radiol Surg. 2017; 12(9):1599-1605.

PMID: 28233166 PMC: 5568989. DOI: 10.1007/s11548-017-1540-6.


Design and development of a mobile image overlay system for needle interventions.

Anand M, King F, Ungi T, Lasso A, Rudan J, Jayender J Annu Int Conf IEEE Eng Med Biol Soc. 2015; 2014:6159-62.

PMID: 25571403 PMC: 4437519. DOI: 10.1109/EMBC.2014.6945035.


On mixed reality environments for minimally invasive therapy guidance: systems architecture, successes and challenges in their implementation from laboratory to clinic.

Linte C, Davenport K, Cleary K, Peters C, Vosburgh K, Navab N Comput Med Imaging Graph. 2013; 37(2):83-97.

PMID: 23632059 PMC: 3796657. DOI: 10.1016/j.compmedimag.2012.12.002.


Mental visualization of objects from cross-sectional images.

Wu B, Klatzky R, Stetten G Cognition. 2012; 123(1):33-49.

PMID: 22217386 PMC: 3278572. DOI: 10.1016/j.cognition.2011.12.004.