» Articles » PMID: 11265007

Fixation of Periprosthetic Femoral Shaft Fractures: a Biomechanical Comparison of Two Techniques

Overview
Journal J Orthop Trauma
Date 2001 Mar 27
PMID 11265007
Citations 14
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To determine which of two currently used techniques for the treatment of periprosthetic femoral shaft fractures provides the greater fixation rigidity and strength.

Design: A laboratory study using six matched pairs of femurs.

Methods: Embalmed femur prosthesis constructs had a simulated periprosthetic fracture created and were fixed with a plate with proximal cables and distal bicortical screws (Ogden concept) or two allograft struts and cables. Fixation stability was compared in various loading modalities before and after cycling. They were then tested to failure.

Outcome Measurements: Fixation rigidity was defined as the ratio of applied load to the amount of displacement at the fracture.

Results: In all loading modalities, the Ogden construct was more rigid than the allograft strut fixation. The Ogden construct required 1,295 newtons for failure and the allograft strut fixation required 950 newtons (p < 0.05).

Conclusion: The Ogden construct provided a more rigid and stronger initial fixation of a periprosthetic fracture than did the allograft construct.

Citing Articles

Treatment of Bifocal Periprosthetic Fractures above and below a Knee after Tumor using Spanning Ilizarov Device: A Case Report.

Lerner A, Jakusonoka R, Jumtins A, Rothem D J Orthop Case Rep. 2023; 13(9):33-37.

PMID: 37753117 PMC: 10519321. DOI: 10.13107/jocr.2023.v13.i09.3866.


A New System for Periprosthetic Fracture Stabilization-A Biomechanical Comparison.

Rau D, Russow G, Heyland M, Wulsten D, Kosters C, Schmolz W J Clin Med. 2022; 11(3).

PMID: 35160342 PMC: 8836720. DOI: 10.3390/jcm11030892.


Biomechanics of periprosthetic femur fractures and early weightbearing.

Khwaja A, Mahoney W, Johnson J, Trompeter A, Lowe J Eur J Orthop Surg Traumatol. 2021; 31(5):861-869.

PMID: 33852066 DOI: 10.1007/s00590-021-02969-3.


A novel reduction device for the minimally invasive treatment of femoral shaft fractures.

Jiang W, Lin Y, Kotian R, Xie W, Li Y, Li G Am J Transl Res. 2020; 12(7):3917-3925.

PMID: 32774745 PMC: 7407717.


Monofilament Cerclage Wiring Fixation with Locking Plates for Distal Femoral Fracture: Is it Appropriate?.

Lee S, Choi Y, Kweon S Indian J Orthop. 2019; 53(6):689-694.

PMID: 31673167 PMC: 6804377. DOI: 10.4103/ortho.IJOrtho_269_18.