» Articles » PMID: 11242287

Clinically Significant Blunt Cardiac Trauma: Role of Serum Troponin Levels Combined with Electrocardiographic Findings

Overview
Journal J Trauma
Specialty Emergency Medicine
Date 2001 Mar 10
PMID 11242287
Citations 34
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The true importance of blunt cardiac trauma (BCT) is related to the cardiac complications arising from it. Diagnostic tests that can predict accurately if such complications will develop or not may allow early and aggressive monitoring or early discharge. We investigated the role of two simple and convenient tests, serum cardiac troponin I (cTnI) and electrocardiogram (ECG), when used to identify patients at risk of cardiac complications after BCT.

Methods: Over a 10-month period, 115 patients with evidence of significant blunt thoracic trauma were prospectively followed to identify the presence of clinically significant BCT (Sig-BCT), defined as cardiogenic shock, arrhythmias requiring treatment, or structural cardiac abnormalities directly related to the cardiac trauma. An ECG was obtained at admission and at 8 hours. Cardiac troponin I was measured at admission, at 4 hours, and at 8 hours. Transthoracic echocardiography was performed when clinically indicated. The sensitivity, specificity, and positive and negative predictive values of ECG and cTnI to identify Sig-BCT were calculated. Clinical risk factors for Sig-BCT were examined by univariate and multivariate analysis.

Results: Nineteen patients (16.5%) were diagnosed with Sig-BCT and, in 18 of them, symptoms presented within 24 hours of admission. Abnormal electrocardiographic findings were detected in 58 patients (50%) and elevated cTnI levels in 27 (23.5%). Electrocardiography and cTnI had positive predictive values of 28% and 48% and negative predictive values of 95% and 93%, respectively. However, when both tests were abnormal (positive) or normal (negative), the positive and negative predictive values increased to 62% and 100%, respectively. Other independent risk factors for Sig-BCT were head injury, spinal injury, history of preexisting cardiac disease, and a chest Abbreviated Injury Score greater than 2.

Conclusion: The combination of ECG and cTnI identifies reliably the presence or absence of Sig-BCT. Patients with an abnormal ECG and cTnI need close monitoring for at least 24 hours. Patients with a normal admission ECG and cTnI can be safely discharged in the absence of other injuries.

Citing Articles

Penetrating cardiac injury caused by multiple rib fractures following high-energy trauma: Usefulness of the exploratory video-assisted thoracoscopic surgery.

Tetsumoto K, Takayama M, Koyama T, Kayawake H, Saito M, Nakamura K Acute Med Surg. 2024; 11(1):e938.

PMID: 38596161 PMC: 11002335. DOI: 10.1002/ams2.938.


Clinical Interpretation of Serum Troponin in the Era of High-Sensitivity Testing.

Maayah M, Grubman S, Allen S, Ye Z, Park D, Vemmou E Diagnostics (Basel). 2024; 14(5).

PMID: 38472975 PMC: 10930800. DOI: 10.3390/diagnostics14050503.


Karate kick-induced myocardial contusion.

Doornkamp R, van Winden D, Buiten M, Josephus Jitta D BMJ Case Rep. 2024; 17(1).

PMID: 38272515 PMC: 10826487. DOI: 10.1136/bcr-2023-257082.


Accuracy of diagnostic tests in cardiac injury after blunt chest trauma: a systematic review and meta-analysis.

Kyriazidis I, Jakob D, Hernandez Vargas J, Franco O, Degiannis E, Dorn P World J Emerg Surg. 2023; 18(1):36.

PMID: 37245048 PMC: 10225099. DOI: 10.1186/s13017-023-00504-9.


Risk factors and outcomes in pediatric blunt cardiac injuries.

Emigh B, Grigorian A, Dilday J, Condon F, Nahmias J, Schellenberg M Pediatr Surg Int. 2023; 39(1):195.

PMID: 37160488 DOI: 10.1007/s00383-023-05478-y.