» Articles » PMID: 11242273

Thoracic Pedicle: Surgical Anatomic Evaluation and Relations

Overview
Journal J Spinal Disord
Date 2001 Mar 10
PMID 11242273
Citations 28
Authors
Affiliations
Soon will be listed here.
Abstract

This anatomic study investigated the thoracic pedicle and its relations. The objective was to emphasize the importance of the thoracic pedicle for transpedicular screw fixation to avoid complications during surgery. Twenty cadavers were used to observe the cervical pedicle and its relations. The isthmus of the pedicle was exposed after removal of whole-posterior bony elements, including spinous processes, laminas, lateral masses, and the inferior and superior facets. The pedicle width and height, interpedicular distance, pedicle-inferior nerve root distance, pedicle-superior nerve root distance, pedicle-dural sac distance, root exit angle, and nerve root diameter were measured. There was no distance between the pedicle and dural sac in eight specimens. There was, however, a short distance in 12 remaining specimens in the upper and lower thoracic regions. The distances between the thoracic pedicle and the adjacent nerve roots ranged from 1.5 to 6.7 mm and 0.8 to 6.0 mm superiorly and inferiorly at all levels. The mean pedicle height and width at T1-T12 ranged from 2.9 to 11.4 mm and 6.2 to 21.3 mm, respectively. The interpedicular distance decreased gradually from T1 to T5 and then increased gradually to T12. The mean root exit angle decreased consistently from 104 degrees to 60 degrees. The nerve root diameter was between 2.3 and 2.5 mm at the T1-T5 level and then increased consistently from 2.5 to 3.7 mm. All significant differences were noted at p < 0.05 and p < 0.01. The following suggestions are made based on these results. 1) More care should be taken when a transpedicular screw is placed in the horizontal plane. 2) Improper medial placement of the pedicle screw, especially in the middle thoracic spine, should be avoided, and the anatomic variations between individuals should be considered. 3) Because of substantial variations in the size of thoracic pedicles, utmost attention should be given to the findings of a computed tomographic evaluation before thoracic transpedicular fixation is begun.

Citing Articles

Incidence of pedicle breach following open and minimally invasive spinal instrumentation: A postoperative CT analysis of 513 pedicle screws applied under fluoroscopic guidance.

Chong X, Kumar A, Yang E, Kaliya-Perumal A, Oh J Biomedicine (Taipei). 2021; 10(2):30-35.

PMID: 33854918 PMC: 7608845. DOI: 10.37796/2211-8039.1016.


Comparison of the accuracy of cannulated pedicle screw versus conventional pedicle screw in the treatment of adolescent idiopathic scoliosis: A randomized retrospective study.

Yilar S Medicine (Baltimore). 2019; 98(10):e14811.

PMID: 30855502 PMC: 6417530. DOI: 10.1097/MD.0000000000014811.


Clinical significance of superior articular process as a reference point for free-hand pedicle screw insertion in thoracic spine.

Kim T, Lee S, Yang J, Hong J, Suh S Medicine (Baltimore). 2018; 97(7):e9907.

PMID: 29443765 PMC: 5839810. DOI: 10.1097/MD.0000000000009907.


Cadaveric study for ideal dorsal pedicle screw entry point.

Sonone S, Dahapute A, Pal M, Virani S, Gala R J Craniovertebr Junction Spine. 2017; 8(2):127-131.

PMID: 28694596 PMC: 5490346. DOI: 10.4103/jcvjs.JCVJS_5_17.


Ideal T1 laminar screw fixation based on computed tomography morphometry.

Wang X, Zheng X, Long H, Chen W, Cheng X, Huang Y BMC Musculoskelet Disord. 2017; 18(1):241.

PMID: 28577531 PMC: 5457552. DOI: 10.1186/s12891-017-1604-3.