[123I]IPT Binding to the Presynaptic Dopamine Transporter: Variation of Intra- and Interobserver Data Evaluation in Parkinsonian Patients and Controls
Overview
Authors
Affiliations
Imaging the presynaptic dopamine transporter with cocaine analogues and single-photon emission tomography (SPET) has proven to be a potential diagnostic tool for classifying the extent and degree of dopaminergic nerve cell loss. For correct interpretation of scan results, however, knowledge of the intra-/interobserver variation of data evaluation is mandatory. Iodine-123 labelled N-(3-iodopropen-2-yl)-2beta-carbomethoxy-3beta-(chlorophenyl)tropane ([123I]IPT) SPET data of 10 controls and 30 parkinsonian patients with varying degrees of reduced IPT binding were analysed twice by an expert (intraobserver) and once by a less experienced physician in training (interobserver). For semiquantitative evaluation of specific IPT binding, ratios between total striatum, caudate and putamen and a background region were calculated. No significant differences were observed for either the intra- or the interobserver analyses. Variation was lower in controls than in the patient group. Overall variation indices were below 5%. Variation in interobserver results was only slightly higher than that in intraobserver results. The intra-/interobserver results showed highly significant correlations (r = 0.99). The intraclass correlation was higher than 0.9 for all evaluations. Our results indicate that the specific presynaptic striatal dopamine transporter binding assessed with IPT-SPET may be reproducibly analysed by the same and different observers in controls as well as in patients with varying degrees of reduced binding.
Kaewchur T, Khiewvan B, Chamroonrat W, Lolekha P, Phokaewvarangkul O, Thientunyakit T Asia Ocean J Nucl Med Biol. 2024; 12(2):86-107.
PMID: 39050239 PMC: 11263770. DOI: 10.22038/AOJNMB.2023.75619.1531.
Crespo C, Gallego J, Cot A, Falcon C, Bullich S, Pareto D Eur J Nucl Med Mol Imaging. 2008; 35(7):1334-42.
PMID: 18335217 DOI: 10.1007/s00259-007-0711-z.
Tossici-Bolt L, Hoffmann S, Kemp P, Mehta R, Fleming J Eur J Nucl Med Mol Imaging. 2006; 33(12):1491-9.
PMID: 16858570 DOI: 10.1007/s00259-006-0155-x.
Pogarell O, Koch W, Gildehaus F, Kupsch A, Lindvall O, Oertel W Eur J Nucl Med Mol Imaging. 2006; 33(4):407-11.
PMID: 16447045 DOI: 10.1007/s00259-005-0032-z.
Cross-camera comparison of SPECT measurements of a 3-D anthropomorphic basal ganglia phantom.
Koch W, Radau P, Munzing W, Tatsch K Eur J Nucl Med Mol Imaging. 2006; 33(4):495-502.
PMID: 16435116 DOI: 10.1007/s00259-005-0036-8.