Improved Extraction Torque of Hydroxyapatite-coated Pedicle Screws

Overview
Journal Eur Spine J
Specialty Orthopedics
Date 2001 Feb 24
PMID 11189923
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Loosening of the screws is a problem in instrumentation with pedicle screws. Coating with hydroxyapatite improves the holding characteristics for metal implants, but the possible effects on the anchorage of pedicle screws have not been described. In this study, seven patients were operated on with spinal instrumentation using four stainless steel pedicle screws. Hydroxyapatite-coated screws were used in either the upper or the lower of the instrumented levels. The insertion torque was measured. In four cases the screws were removed after 10-22 months and the extraction torque was measured. The mean insertion torque was found to be significantly greater in the hydroxyapatite-coated screws (107 Ncm) than in the standard screws (76 Ncm). In three cases, the extraction torque for the hydroxyapatite-coated screws exceeded the range for the torque wrench (600 Ncm), while the conventional screws were loose (< 5 Ncm). In one case, the extraction torque was 475 and 550 Ncm for the coated screws, and 5 and 25 Ncm for the conventional screws. The difference in extraction torque was significant. Hydroxyapatite coating was shown to have improved the purchase of pedicle screws very effectively. By using fully coated screws, as in the present study, extraction was extremely difficult compared to extraction of conventional stainless steel screws, which were regularly loose. By reducing the area of the screws that is coated, it may be possible to achieve an enhanced purchase while extraction will be easier when compared to fully coated screws.

Citing Articles

Safety of terminally gamma-ray-sterilized screws coated with fibroblast growth factor 2-calcium phosphate composite layers in non-human primates.

Matsumoto Y, Mutsuzaki H, Nagashima K, Hara Y, Yanagisawa Y, Okano E J Artif Organs. 2022; 26(3):192-202.

PMID: 35941264 DOI: 10.1007/s10047-022-01352-1.


Beyond the pedicle screw-a patent review.

de Kater E, Sakes A, Edstrom E, Elmi-Terander A, Kraan G, Breedveld P Eur Spine J. 2022; 31(6):1553-1565.

PMID: 35380271 DOI: 10.1007/s00586-022-07193-z.


Initial clinical trial of pins coated with fibroblast growth factor-2-apatite composite layer in external fixation of distal radius fractures.

Yanagisawa Y, Ito A, Hara Y, Mutsuzaki H, Murai S, Fujii K J Orthop. 2019; 16(1):69-73.

PMID: 30662242 PMC: 6324763. DOI: 10.1016/j.jor.2018.12.012.


Reducing the risk of impaired bone apposition to titanium screws with the use of fibroblast growth factor-2-apatite composite layer coating.

Fujii K, Ito A, Mutsuzaki H, Murai S, Sogo Y, Hara Y J Orthop Surg Res. 2017; 12(1):1.

PMID: 28057033 PMC: 5217243. DOI: 10.1186/s13018-016-0501-z.


The efficacy of hydroxyapatite for screw augmentation in osteoporotic patients.

Jang S, Lee J, Cho J, Lee H, Lee S Neurol Med Chir (Tokyo). 2013; 53(12):875-81.

PMID: 24201099 PMC: 4508726. DOI: 10.2176/nmc.oa2012-0346.