» Articles » PMID: 11092181

[Computer-assisted Insertion of Zygomatic Implants (Brånemark System) After Extensive Tumor Surgery]

Overview
Date 2000 Nov 25
PMID 11092181
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Installation of fixtures for prosthetic reconstruction of the upper jaw in patients with extensive bone and soft tissue defects is still a challenge. The new fixture developed by Brånemark System achieves immediate prosthetic reconstruction by anchoring implants in the zygomatic bone to offer sufficient support without bone grafts. The dimension of these zygomatic fixtures and the complex anatomy due to previous surgical procedures demand specific treatment for a precise and safe insertion of the implants. On the basis of an axial spiral CT data set, the STN navigation system (Stryker-Leibinger/Zeiss) was used for preoperative planning and intraoperative control of the insertion of zygomatic fixtures after subtotal maxillectomy. Computer-assisted insertion of zygomatic fixtures was successfully completed. The implants could be positioned precisely as preoperatively planned. The use of zygomatic fixtures after ablative tumor surgery with resection of the maxillary bone provides immediate prosthetic reconstruction without additional bone grafting. Computer-assisted insertion of these implants improves preoperative planning and facilitates clinical procedure.

Citing Articles

A modified protocol merging two published techniques for computer guided zygomatic implants surgery: a technical note.

Abouzeid O, Gaber R, Maergy H, Hany H, Abdelmohsen K, Elkassaby M BMC Oral Health. 2024; 24(1):1273.

PMID: 39449100 PMC: 11515538. DOI: 10.1186/s12903-024-05010-1.


Prosthodontic rehabilitation of patients with a unilateral subtotal maxillectomy using a customised subperiosteal zygomatic implant: a post-COVID-19 mucormycosis.

Basavaraju R, Shetty S, Pugazhendhi P, Aradya A BMJ Case Rep. 2024; 17(1).

PMID: 38199654 PMC: 10806840. DOI: 10.1136/bcr-2023-258338.


Reliability and accuracy of dynamic navigation for zygomatic implant placement.

Wu Y, Tao B, Lan K, Shen Y, Huang W, Wang F Clin Oral Implants Res. 2022; 33(4):362-376.

PMID: 35113463 PMC: 9305866. DOI: 10.1111/clr.13897.


A New Strategy for Patient-Specific Implant-Borne Dental Rehabilitation in Patients With Extended Maxillary Defects.

Korn P, Gellrich N, Jehn P, Spalthoff S, Rahlf B Front Oncol. 2021; 11:718872.

PMID: 34956858 PMC: 8708135. DOI: 10.3389/fonc.2021.718872.


Accuracy of digital planning in zygomatic implants.

Xing Gao B, Iglesias-Velazquez O, G F Tresguerres F, Rodriguez Gonzalez Cortes A, F Tresguerres I, Ortega Aranegui R Int J Implant Dent. 2021; 7(1):65.

PMID: 34291352 PMC: 8295422. DOI: 10.1186/s40729-021-00350-x.