» Articles » PMID: 11059167

Nonlinear Transient Chirp Signal Modeling of the Aortic and Pulmonary Components of the Second Heart Sound

Overview
Date 2000 Nov 4
PMID 11059167
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

This paper describes a new approach based on the time-frequency representation of transient nonlinear chirp signals for modeling the aortic (A2) and the pulmonary (P2) components of the second heart sound (S2). It is demonstrated that each component is a narrow-band signal with decreasing instantaneous frequency defined by its instantaneous amplitude and its instantaneous phase. Each component is also a polynomial phase signal, the instantaneous phase of which can be accurately represented by a polynomial having an order of thirty. A dechirping approach is used to obtain the instantaneous amplitude of each component while reducing the effect of the background noise. The analysis-synthesis procedure is applied to 32 isolated A2 and 32 isolated P2 components recorded in four pigs with pulmonary hypertension. The mean +/- standard deviation of the normalized root-mean-squared error (NRMSE) and the correlation coefficient (rho) between the original and the synthesized signal components were: NRMSE = 2.1 +/- 0.3% and rho = 0.97 +/- 0.02 for A2 and NRMSE = 2.52 +/- 0.5% and rho = 0.96 +/- 0.02 for P2. These results confirm that each component can be modeled as mono-component nonlinear chirp signals of short duration with energy distributions concentrated along its decreasing instantaneous frequency.

Citing Articles

Deep Layer Kernel Sparse Representation Network for the Detection of Heart Valve Ailments from the Time-Frequency Representation of PCG Recordings.

Ghosh S, Ponnalagu R, Tripathy R, Rajendra Acharya U Biomed Res Int. 2021; 2020:8843963.

PMID: 33415163 PMC: 7769642. DOI: 10.1155/2020/8843963.


Second heart sound splitting as an indicator of interventricular mechanical dyssynchrony using a novel splitting detection algorithm.

Luo H, Westphal P, Shahmohammadi M, Heckman L, Kuiper M, Cornelussen R Physiol Rep. 2021; 9(1):e14687.

PMID: 33400386 PMC: 7785055. DOI: 10.14814/phy2.14687.


Data assimilation and multisource decision-making in systems biology based on unobtrusive Internet-of-Things devices.

Tang W, Ho W, Chen Y Biomed Eng Online. 2018; 17(Suppl 2):147.

PMID: 30396337 PMC: 6218968. DOI: 10.1186/s12938-018-0574-5.


A Phonocardiographic-Based Fiber-Optic Sensor and Adaptive Filtering System for Noninvasive Continuous Fetal Heart Rate Monitoring.

Martinek R, Nedoma J, Fajkus M, Kahankova R, Konecny J, Janku P Sensors (Basel). 2017; 17(4).

PMID: 28420215 PMC: 5426540. DOI: 10.3390/s17040890.


Detection of the valvular split within the second heart sound using the reassigned smoothed pseudo Wigner-Ville distribution.

Djebbari A, Bereksi-Reguig F Biomed Eng Online. 2013; 12:37.

PMID: 23631738 PMC: 3706289. DOI: 10.1186/1475-925X-12-37.