» Articles » PMID: 11048392

The Physical Mechanisms of Complete Denture Retention

Overview
Journal Br Dent J
Specialty Dentistry
Date 2000 Oct 26
PMID 11048392
Citations 14
Authors
Affiliations
Soon will be listed here.
Abstract

The purpose of this article is to assist the practitioner to understand which factors are relevant to complete denture retention in the light of the current understanding of physics and materials science and thus to guide design. Atmospheric pressure, vacuum, adhesion, cohesion, surface tension, viscosity, base adaption, border seal, seating force and muscular control have all been cited at one time or another as major or contributory factors, but usually as an opinion without proper reference to fundamental principles. Although there has been a detailed analysis published, it seems appropriate that a restatement of the points in a collated form be made. In fact, denture retention is a dynamic issue dependent on the control of the flow of interposed fluid and thus its viscosity and film thickness, while the timescale of displacement loading affects the assessment. Surface tension forces at the periphery contribute to retention, but the most important concerns are good base adaptation and border seal. These must be achieved if full advantage is to be taken of the saliva flow-related effects.

Citing Articles

Impact of the Physiological Parameters of the Oral Cavity on the Mechanical Properties of Zinc-stabilized and Zinc-free Adhesive Creams: A Comparative In Vitro Study.

Reymann J, Narayanan Ramakrishnan A, Ludtka C, Hey J, Kiesow A, Schwan S J Adhes Dent. 2025; 27:21-29.

PMID: 40063077 PMC: 11904830. DOI: 10.3290/j.jad.c_1871.


Effect of aging on dimensional accuracy and color stability of CAD-CAM milled and 3D-printed denture base resins: a comparative in-vitro study.

Gad M, Abdelhamid A, ElSamahy M, Abolgheit S, Hanno K BMC Oral Health. 2024; 24(1):1124.

PMID: 39327573 PMC: 11429381. DOI: 10.1186/s12903-024-04848-9.


The wettability of complete denture base materials constructed by conventional versus digital techniques: an in-vitro study.

Hanno K, Metwally N BMC Oral Health. 2024; 24(1):1081.

PMID: 39272090 PMC: 11395271. DOI: 10.1186/s12903-024-04800-x.


Evaluation of the effect of thermocycling on the trueness and precision of digitally fabricated complete denture bases.

Zeidan A, Helal M BMC Oral Health. 2024; 24(1):983.

PMID: 39180008 PMC: 11344438. DOI: 10.1186/s12903-024-04636-5.


The accuracy and retention of presurgical infant orthopaedics constructed from different polymer materials: A comparative study.

Oday R, Abid M, Dziedzic A J Taibah Univ Med Sci. 2024; 19(2):379-389.

PMID: 38370166 PMC: 10874750. DOI: 10.1016/j.jtumed.2024.01.005.