» Articles » PMID: 11045503

Recent and Future Developments of Liquid Chromatography in Pesticide Trace Analysis

Overview
Journal J Chromatogr A
Publisher Elsevier
Specialty Chemistry
Date 2000 Oct 25
PMID 11045503
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Until recently, the application of liquid chromatography (LC) in pesticide analysis was usually focused on groups of compounds or single compounds for which no suitable conditions were available for analysis with gas chromatography (GC). However, recent developments in both detection and column material technology show that LC significantly enlarged its scope in this field of analysis. Obviously, the most striking example is the rather abrupt transition of LC coupled to mass spectrometric detection (MS) from an experimental and scientifically fashionable technique to a robust, sensitive and selective detection mode rendering LC-MS being increasingly used in pesticide trace analysis. Other recent major developments originate from the innovation of new LC column packing materials, viz. immuno-affinity sorbents, restricted access medium materials and molecular imprinted polymers improving considerably the screening of polar pesticides by means of reversed-phase LC with UV detection. In this review the merits and perspectives of these important LC developments and their impact to current and future applications in pesticide trace analysis are presented and discussed.

Citing Articles

Electrochemical Biosensor Based on Well-Dispersed Boron Nitride Colloidal Nanoparticles and DNA Aptamers for Ultrasensitive Detection of Carbendazim.

Wang R, Qin Y, Liu X, Li Y, Lin Z, Nie R ACS Omega. 2021; 6(41):27405-27411.

PMID: 34693161 PMC: 8529661. DOI: 10.1021/acsomega.1c04326.


Cholinesterases and Engineered Mutants for the Detection of Organophosphorus Pesticide Residues.

Xu Y, Li F, Ndikuryayo F, Yang W, Wang H Sensors (Basel). 2018; 18(12).

PMID: 30563111 PMC: 6312092. DOI: 10.3390/s18124281.


The subchronic exposure to malathion, an organophosphate pesticide, causes lipid peroxidation, oxidative stress, and tissue damage in rats: the protective role of resveratrol.

Akbel E, Arslan-Acaroz D, Demirel H, Kucukkurt I, Ince S Toxicol Res (Camb). 2018; 7(3):503-512.

PMID: 30090600 PMC: 6062150. DOI: 10.1039/c8tx00030a.


A new surface plasmon resonance immunosensor for triazine pesticide determination in bovine milk: a comparison with conventional amperometric and screen-printed immunodevices.

Tomassetti M, Martini E, Campanella L, Favero G, Sanzo G, Mazzei F Sensors (Basel). 2015; 15(5):10255-70.

PMID: 25942643 PMC: 4482009. DOI: 10.3390/s150510255.


Performance of a cyanobacteria whole cell-based fluorescence biosensor for heavy metal and pesticide detection.

Shing W, Heng L, Surif S Sensors (Basel). 2013; 13(5):6394-404.