» Articles » PMID: 11045345

Comparison of Immersion Ultrasound Biometry and Partial Coherence Interferometry for Intraocular Lens Calculation According to Haigis

Overview
Specialty Ophthalmology
Date 2000 Oct 25
PMID 11045345
Citations 171
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The precision of intraocular lens (IOL) calculation is essentially determined by the accuracy of the measurement of axial length. In addition to classical ultrasound biometry, partial coherence interferometry serves as a new optical method for axial length determination. A functional prototype from Carl Zeiss Jena implementing this principle was compared with immersion ultrasound biometry in our laboratory.

Patients And Methods: In 108 patients attending the biometry laboratory for planning of cataract surgery, axial lengths were additionally measured optically. Whereas surgical decisions were based on ultrasound data, we used postoperative refraction measurements to calculate retrospectively what results would have been obtained if optical axial length data had been used for IOL calculation. For the translation of optical to geometrical lengths, five different conversion formulas were used, among them the relation which is built into the Zeiss IOL-Master. IOL calculation was carried out according to Haigis with and without optimization of constants.

Results: On the basis of ultrasound immersion data from our Grieshaber Biometric System (GBS), postoperative refraction after implantation of a Rayner IOL type 755 U was predicted correctly within +/- 1 D in 85.7% and within +/- 2 D in 99% of all cases. An analogous result was achieved with optical axial length data after suitable transformation of optical path lengths into geometrical distances.

Conclusions: Partial coherence interferometry is a noncontact, user- and patient-friendly method for axial length determination and IOL planning with an accuracy comparable to that of high-precision immersion ultrasound.

Citing Articles

Evaluation of Axial Length and Refractive Outcomes in Patients With Dense Vitreous Hemorrhage Who Have Phacovitrectomy.

Ozturk Y, Agin A, Yucel Gencoglu A J Vitreoretin Dis. 2025; :24741264251322211.

PMID: 39991041 PMC: 11840823. DOI: 10.1177/24741264251322211.


Intraocular lens calculation formula selection for short eyes: based on axial length and anterior chamber depth.

Gao R, Zhang J, Han X, Huang Y, Huang R, Ye J BMC Ophthalmol. 2025; 25(1):21.

PMID: 39819497 PMC: 11737209. DOI: 10.1186/s12886-024-03793-z.


Evaluation of keratometric and total corneal astigmatism measurements from optical biometers and anterior segment tomographers and mapping to reconstructed corneal astigmatism vector components.

Langenbucher A, Szentmary N, Cayless A, Hoffmann P, Wendelstein J, Pantanelli S PLoS One. 2025; 20(1):e0313574.

PMID: 39775332 PMC: 11709277. DOI: 10.1371/journal.pone.0313574.


A New Intraocular Lens Power Formula Integrating an Artificial Intelligence-Powered Estimation for Effective Lens Position Based on Chinese Eyes.

Lou W, Zhou W, Wu M, Jin H Transl Vis Sci Technol. 2024; 13(10):40.

PMID: 39476087 PMC: 11534016. DOI: 10.1167/tvst.13.10.40.


[Basic aspects of IOL calculation].

Preussner P, Langenbucher A Ophthalmologie. 2024; 121(11):858-865.

PMID: 39446170 DOI: 10.1007/s00347-024-02129-y.