» Articles » PMID: 10947010

Do's and Don'ts in Fourier Analysis of Steady-state Potentials

Overview
Journal Doc Ophthalmol
Specialty Ophthalmology
Date 2000 Aug 18
PMID 10947010
Citations 78
Authors
Affiliations
Soon will be listed here.
Abstract

Fourier analysis is a powerful tool in signal analysis that can be very fruitfully applied to steady-state evoked potentials (flicker ERG, pattern ERG, VEP, etc.). However, there are some inherent assumptions in the underlying discrete Fourier transform (DFT) that are not necessarily fulfilled in typical electrophysiological recording and analysis conditions. Furthermore, engineering software-packages may be ill-suited and/or may not fully exploit the information of steady-state recordings. Specifically: * In the case of steady-state stimulation we know more about the stimulus than in standard textbook situations (exact frequency, phase stability), so 'windowing' and calculation of the 'periodogram' are not necessary. * It is mandatory to choose an integer relationship between sampling rate and frame rate when employing a raster-based CRT stimulator. * The analysis interval must comprise an exact integer number (e.g., 10) of stimulus periods. * The choice of the number of stimulus periods per analysis interval needs a wise compromise: A high number increases the frequency resolution, but makes artifact removal difficult; a low number 'spills' noise into the response frequency. * There is no need to feel tied to a power-of-two number of data points as required by standard FFT, 'resampling' is an easy and efficient alternative. * Proper estimates of noise-corrected Fourier magnitude and statistical significance can be calculated that take into account the non-linear superposition of signal and noise. These aspects are developed in an intuitive approach with examples using both simulations and recordings. Proper use of Fourier analysis of our electrophysiological records will reduce recording time and/or increase the reliability of physiologic or pathologic interpretations.

Citing Articles

Measuring self-similarity in empirical signals to understand musical beat perception.

Lenc T, Lenoir C, Keller P, Polak R, Mulders D, Nozaradan S Eur J Neurosci. 2025; 61(2):e16637.

PMID: 39853878 PMC: 11760665. DOI: 10.1111/ejn.16637.


Light-based gamma entrainment with novel invisible spectral flicker stimuli.

Hansen L, Carstensen M, Henney M, Nguyen N, Thorning-Schmidt M, Broeng J Sci Rep. 2024; 14(1):29747.

PMID: 39613776 PMC: 11606973. DOI: 10.1038/s41598-024-75448-4.


SSVEP-based visual acuity threshold estimation: linear extrapolation to noise level baseline with various noise definition criteria.

Zheng X, Wei X, Xu G, Zhang R Cogn Neurodyn. 2024; 18(4):1641-1650.

PMID: 39104705 PMC: 11297861. DOI: 10.1007/s11571-023-10036-2.


Quantifying Population-level Neural Tuning Functions Using Ricker Wavelets and the Bayesian Bootstrap.

Ahumada L, Panitz C, Traiser C, Gilbert F, Ding M, Keil A bioRxiv. 2024; .

PMID: 38826264 PMC: 11142194. DOI: 10.1101/2024.05.22.595429.


Reduced contrast sensitivity, pattern electroretinogram ratio, and diminished a-wave amplitude in patients with major depressive disorder.

Friedel E, Tebartz van Elst L, Beringer M, Endres D, Runge K, Maier S Eur Arch Psychiatry Clin Neurosci. 2024; .

PMID: 38805071 DOI: 10.1007/s00406-024-01826-8.


References
1.
Norcia A, Tyler C, Hamer R, Wesemann W . Measurement of spatial contrast sensitivity with the swept contrast VEP. Vision Res. 1989; 29(5):627-37. DOI: 10.1016/0042-6989(89)90048-5. View

2.
Bach M, Meigen T, Strasburger H . Raster-scan cathode-ray tubes for vision research--limits of resolution in space, time and intensity, and some solutions. Spat Vis. 1997; 10(4):403-14. DOI: 10.1163/156856897x00311. View

3.
Simon F . The phase of PVEP in Maxwellian view: influence of contrast, spatial and temporal frequency. Vision Res. 1992; 32(4):591-9. DOI: 10.1016/0042-6989(92)90175-i. View

4.
Marmor M, Zrenner E . Standard for clinical electroretinography (1999 update). International Society for Clinical Electrophysiology of Vision. Doc Ophthalmol. 2000; 97(2):143-56. DOI: 10.1023/a:1002016531591. View

5.
Meigen T, Bach M . On the statistical significance of electrophysiological steady-state responses. Doc Ophthalmol. 2000; 98(3):207-32. DOI: 10.1023/a:1002097208337. View