» Articles » PMID: 10895825

Effect of Formalin Tissue Fixation and Processing on Immunohistochemistry

Overview
Date 2000 Jul 15
PMID 10895825
Citations 157
Authors
Affiliations
Soon will be listed here.
Abstract

Although immunohistochemistry is routinely performed by many pathology laboratories, its standardization still lags behind. A major cause of variation in the reproducibility of immunohistochemical staining is induced by tissue fixation and, to a lesser degree, tissue processing. This report, stemming from the first meeting of the International Consensus Group on Standardization and Quality Control (ICGSQC) in Nice, France, summarizes the problem and suggests solutions to begin to achieve standardization of fixation and processing. Most laboratories use neutral-buffered formalin (10%) for tissue fixation which introduces cross-links, whereas coagulative fixatives are less popular. Problems with formalin fixation comprise delay of fixation and variations in the duration of the fixation mainly. Solutions to these problems could be to start fixation soon (<30 min) after surgical removal of the tissue and to avoid overfixation (>24-48 hrs). For tissue processing, the most important problem is inadequate tissue dehydration prior to paraffin embedding. This can be prevented by preparing all solutions freshly every week, depending on the volume of tissue processed. If consistently applied, these procedures could eliminate some of the sources of variation in immunohistochemical stains.

Citing Articles

Three-Dimensional Microscopic Characteristics of the Human Uterine Cervix Evaluated by Microtomography.

Matos A, Aranda O, Marchiori E, Machado A, Da Penha Moreira A, Werner H Diagnostics (Basel). 2025; 15(5).

PMID: 40075850 PMC: 11898730. DOI: 10.3390/diagnostics15050603.


Immuno-oncologic profiling by stage-dependent transcriptome and proteome analyses of spontaneously regressing canine cutaneous histiocytoma.

Loriani Fard A, Haake A, Jovanovic V, Andreotti S, Hummel M, Hempel B PeerJ. 2024; 12:e18444.

PMID: 39619201 PMC: 11606323. DOI: 10.7717/peerj.18444.


Characterization of sub-micrometre-sized voids in fixed human brain tissue using scanning X-ray microdiffraction.

Nepal P, Bashit A, Makowski L J Appl Crystallogr. 2024; 57(Pt 5):1528-1538.

PMID: 39387087 PMC: 11460389. DOI: 10.1107/S1600576724008987.


Approaches and methods to study wildlife cancer.

Giraudeau M, Vincze O, Dupont S, Sepp T, Baines C, Lemaitre J J Anim Ecol. 2024; 93(10):1410-1428.

PMID: 39189422 PMC: 11745198. DOI: 10.1111/1365-2656.14144.


Quantifying Dendritic Arbors In Vitro and In Vivo in Rodent Models.

Wilson R, Badley J, Lein P Methods Mol Biol. 2024; 2831:39-57.

PMID: 39134842 DOI: 10.1007/978-1-0716-3969-6_4.