» Articles » PMID: 10853058

Concordance Between Functional Magnetic Resonance Imaging and Intraoperative Language Mapping

Overview
Publisher Karger
Specialty Neurosurgery
Date 2000 Jun 15
PMID 10853058
Citations 20
Authors
Affiliations
Soon will be listed here.
Abstract

Although the correspondence between functional-magnetic resonance imaging (fMRI) representations of the sensorimotor cortex and intraoperative electrophysiology (including somatosensory evoked potential, SSEP, recordings and direct cortical stimulation) has been reported, a similar correspondence between fMRI and intraoperative localization of the language-sensitive cortex is not as well established. The aim of the present study was to evaluate the concordance between fMRI and intraoperative electrophysiology with respect to the localization of the language-sensitive and sensorimotor cortices. We present the results of 21 patients who underwent language and sensorimotor mapping by fMRI and intraoperative electrophysiology including SSEP recordings (n = 21), direct cortical stimulation of motor cortex (n = 15) and direct cortical stimulation of Broca's and Wernicke's area (n = 5). When responses were obtained with both methods, localization of function concurred in all cases. These observations suggest that fMRI represents a reliable preoperative tool for the identification of language-sensitive areas.

Citing Articles

Preoperative mapping techniques for brain tumor surgery: a systematic review.

Leone A, Carbone F, Spetzger U, Vajkoczy P, Raffa G, Angileri F Front Oncol. 2025; 14():1481430.

PMID: 39839770 PMC: 11747149. DOI: 10.3389/fonc.2024.1481430.


Speech and Language Errors during Awake Brain Surgery and Postoperative Language Outcome in Glioma Patients: A Systematic Review.

Collee E, Vincent A, Dirven C, Satoer D Cancers (Basel). 2022; 14(21).

PMID: 36358884 PMC: 9658495. DOI: 10.3390/cancers14215466.


A New Functional Magnetic Resonance Imaging Localizer for Preoperative Language Mapping Using a Sentence Completion Task: Validity, Choice of Baseline Condition, and Test-Retest Reliability.

Elin K, Malyutina S, Bronov O, Stupina E, Marinets A, Zhuravleva A Front Hum Neurosci. 2022; 16:791577.

PMID: 35431846 PMC: 9006995. DOI: 10.3389/fnhum.2022.791577.


Comparison of short-channel separation and spatial domain filtering for removal of non-neural components in functional near-infrared spectroscopy signals.

Adam Noah J, Zhang X, Dravida S, DiCocco C, Suzuki T, Aslin R Neurophotonics. 2021; 8(1):015004.

PMID: 33598505 PMC: 7881368. DOI: 10.1117/1.NPh.8.1.015004.


Intraoperative Use of Functional MRI for Surgical Decision Making after Limited or Infeasible Electrocortical Stimulation Mapping.

Rigolo L, Essayed W, Tie Y, Norton I, Mukundan Jr S, Golby A J Neuroimaging. 2019; 30(2):184-191.

PMID: 31867823 PMC: 7252738. DOI: 10.1111/jon.12683.