» Articles » PMID: 10823909

Shear Stress-induced Apoptosis of Adherent Neutrophils: a Mechanism for Persistence of Cardiovascular Device Infections

Overview
Specialty Science
Date 2000 May 24
PMID 10823909
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

The mechanisms underlying problematic cardiovascular device-associated infections are not understood. Because the outcome of the acute response to infection is largely dependent on the function of neutrophils, the persistence of these infections suggests that neutrophil function may be compromised because of cellular responses to shear stress. A rotating disk system was used to generate physiologically relevant shear stress levels (0-18 dynes/cm(2); 1 dyne = 10 microN) at the surface of a polyetherurethane urea film. We demonstrate that shear stress diminishes phagocytic ability in neutrophils adherent to a cardiovascular device material, and causes morphological and biochemical alterations that are consistent with those described for apoptosis. Complete neutrophil apoptosis occurred at shear stress levels above 6 dynes/cm(2) after only 1 h. Morphologically, these cells displayed irreversible cytoplasmic and nuclear condensation while maintaining intact membranes. Analysis of neutrophil area and filamentous actin content demonstrated concomitant decreases in both cell area and actin content with increasing levels of shear stress. Neutrophil phagocytosis of adherent bacteria decreased with increasing shear stress. Biochemical alterations included membrane phosphatidylserine exposure and DNA fragmentation, as evaluated by in situ annexin V and terminal deoxynucleotidyltransferase-mediated dUTP end labeling (TUNEL) assays, respectively. The potency of the shear-stress effect was emphasized by comparative inductive studies with adherent neutrophils under static conditions. The combination of tumor necrosis factor-alpha and cycloheximide was ineffective in inducing >21% apoptosis after 3 h. These findings suggest a mechanism through which shear stress plays an important role in the development of bacterial infections at the sites of cardiovascular device implantation.

Citing Articles

Increased phagocytosis capacity of circulating neutrophils in patients on continuous flow ventricular assist device support.

Awad M, Sun W, Han D, Griffith B, Wu Z Artif Organs. 2023; 48(6):636-645.

PMID: 38133151 PMC: 11105991. DOI: 10.1111/aor.14693.


Neutrophil Structural and Functional Alterations After High Mechanical Shear Stress Exposure.

Arias K, Sun W, Han D, Griffith B, Wu Z ASAIO J. 2023; 69(9):841-848.

PMID: 37159479 PMC: 11441310. DOI: 10.1097/MAT.0000000000001985.


MyCTC chip: microfluidic-based drug screen with patient-derived tumour cells from liquid biopsies.

Schwab F, Scheidmann M, Ozimski L, Kling A, Armbrecht L, Ryser T Microsyst Nanoeng. 2022; 8:130.

PMID: 36561926 PMC: 9763115. DOI: 10.1038/s41378-022-00467-y.


Neutrophil dysfunction due to continuous mechanical shear exposure in mechanically assisted circulation in vitro.

Sun W, Zhang J, Shah A, Arias K, Berk Z, Griffith B Artif Organs. 2021; 46(1):83-94.

PMID: 34516005 PMC: 8688241. DOI: 10.1111/aor.14068.


Dielectric Elastomer Actuators, Neuromuscular Interfaces, and Foreign Body Response in Artificial Neuromuscular Prostheses: A Review of the Literature for an In Vivo Application.

Bruschi A, Donati D, Choong P, Lucarelli E, Wallace G Adv Healthc Mater. 2021; 10(13):e2100041.

PMID: 34085772 PMC: 11481036. DOI: 10.1002/adhm.202100041.


References
1.
Kettritz R, Xu Y, Kerren T, Quass P, Klein J, Luft F . Extracellular matrix regulates apoptosis in human neutrophils. Kidney Int. 1999; 55(2):562-71. DOI: 10.1046/j.1523-1755.1999.00280.x. View

2.
Wang I, Anderson J, Marchant R . Platelet-mediated adhesion of Staphylococcus epidermidis to hydrophobic NHLBI reference polyethylene. J Biomed Mater Res. 1993; 27(9):1119-28. DOI: 10.1002/jbm.820270902. View

3.
ELEK S, Conen P . The virulence of Staphylococcus pyogenes for man; a study of the problems of wound infection. Br J Exp Pathol. 1957; 38(6):573-86. PMC: 2083292. View

4.
Sugarman B, Young E . Infections associated with prosthetic devices: magnitude of the problem. Infect Dis Clin North Am. 1989; 3(2):187-98. View

5.
Moazzam F, DeLano F, ZWEIFACH B, Schmid-Schonbein G . The leukocyte response to fluid stress. Proc Natl Acad Sci U S A. 1997; 94(10):5338-43. PMC: 24679. DOI: 10.1073/pnas.94.10.5338. View