» Articles » PMID: 10800033

Adaptive Reconstruction of Phased Array MR Imagery

Overview
Journal Magn Reson Med
Publisher Wiley
Specialty Radiology
Date 2000 May 9
PMID 10800033
Citations 310
Authors
Affiliations
Soon will be listed here.
Abstract

An adaptive implementation of the spatial matched filter and its application to the reconstruction of phased array MR imagery is described. Locally relevant array correlation statistics for the NMR signal and noise processes are derived directly from the set of complex individual coil images, in the form of sample correlation matrices. Eigen-analysis yields an optimal filter vector for the estimated signal and noise array correlation statistics. The technique enables near-optimal reconstruction of multicoil MR imagery without a-priori knowledge of the individual coil field maps or noise correlation structure. Experimental results indicate SNR performance approaching that of the optimal matched filter. Compared to the sum-of-squares technique, the RMS noise level in dark image regions is reduced by as much as the square root of N, where N is the number of coils in the array. The technique is also effective in suppressing localized motion and flow artifacts.

Citing Articles

Ultra-high temporal resolution 4D angiography using arterial spin labeling with subspace reconstruction.

Shen Q, Wu W, Chiew M, Ji Y, Woods J, Okell T Magn Reson Med. 2025; 93(5):1924-1941.

PMID: 40063716 PMC: 11893029. DOI: 10.1002/mrm.30407.


Rosette Spectroscopic Imaging for Whole-Brain Slab Metabolite Mapping at 7T: Acceleration Potential and Reproducibility.

Huang Z, Emir U, Doring A, Klauser A, Xiao Y, Widmaier M Hum Brain Mapp. 2025; 46(4):e70176.

PMID: 40056040 PMC: 11889463. DOI: 10.1002/hbm.70176.


Denoising Improves Cross-Scanner and Cross-Protocol Test-Retest Reproducibility of Diffusion Tensor and Kurtosis Imaging.

Ades-Aron B, Coelho S, Lemberskiy G, Veraart J, Baete S, Shepherd T Hum Brain Mapp. 2025; 46(4):e70142.

PMID: 40051327 PMC: 11885890. DOI: 10.1002/hbm.70142.


SC-GROG followed by L+S reconstruction with multiple sparsity constraints for accelerated Golden-angle-radial DCE-MRI.

Najeeb F, Amjad K, Ullah I, Omer H PLoS One. 2025; 20(2):e0318102.

PMID: 39951435 PMC: 11828349. DOI: 10.1371/journal.pone.0318102.


Joint image reconstruction and segmentation of real-time cardiovascular magnetic resonance imaging in free-breathing using a model based on disentangled representation learning.

Wech T, Schad O, Sauer S, Kleineisel J, Petri N, Nordbeck P J Cardiovasc Magn Reson. 2025; 27(1):101844.

PMID: 39864743 PMC: 11874730. DOI: 10.1016/j.jocmr.2025.101844.