Dynamic Breast MRI with Spiral Trajectories: 3D Versus 2D

Overview
Date 2000 Apr 15
PMID 10767063
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

A three-dimensional (3)D spiral sequence was developed for dynamic breast magnetic resonance (MR) imaging with much improved image quality. Partial Z phase encoding was applied to obtain thinner slices for a coverage of the whole breast. Comparison between the 3D and a previously developed multi-slice 2D spiral sequences was performed on ten healthy volunteers without contrast and five breast patients with gadolinium-diethylene triamine pentaacetic acid (Gd-DTPA). The 3D spiral images had significantly less off-resonance blurring and spiral artifacts. With a small compromise on temporal resolution (7.7 seconds in 2D and 10.6 seconds in 3D), we obtained 32 interpolated 3-5 mm slices (with 20 Z phase encodes) for a full coverage of 10-16 cm breast with the same 1 x 1 mm2 in-plane resolution as the 2D sequence, which had 12 8-13 mm slices. Contrast between glandular and soft tissue in normal breasts was increased by about 25%. The reduced repetition time in the 3D spiral acquisition led to an increased Gd-enhanced signal. The difference between the enhancement of malignant and benign lesions increased by sevenfold. We expect that this new development could lead to improved specificity in characterizing breast lesions using MR imaging.

Citing Articles

Spiral Perfusion Imaging With Consecutive Echoes (SPICE™) for the Simultaneous Mapping of DSC- and DCE-MRI Parameters in Brain Tumor Patients: Theory and Initial Feasibility.

Paulson E, Prah D, Schmainda K Tomography. 2017; 2(4):295-307.

PMID: 28090589 PMC: 5226659. DOI: 10.18383/j.tom.2016.00217.


A comparison of radial keyhole strategies for high spatial and temporal resolution 4D contrast-enhanced MRI in small animal tumor models.

Subashi E, Moding E, Cofer G, MacFall J, Kirsch D, Qi Y Med Phys. 2013; 40(2):022304.

PMID: 23387766 PMC: 3562278. DOI: 10.1118/1.4774050.


Magnetic resonance spectroscopy of the breast at 3T: pre- and post-contrast evaluation for breast lesion characterization.

Kousi E, Tsougos I, Vasiou K, Theodorou K, Poultsidi A, Fezoulidis I ScientificWorldJournal. 2012; 2012:754380.

PMID: 22645448 PMC: 3356737. DOI: 10.1100/2012/754380.


A high spatial resolution 1H magnetic resonance spectroscopic imaging technique for breast cancer with a short echo time.

Hu J, Yu Y, Kou Z, Huang W, Jiang Q, Xuan Y Magn Reson Imaging. 2007; 26(3):360-6.

PMID: 17904326 PMC: 3805364. DOI: 10.1016/j.mri.2007.07.004.


MRI-guided needle localization of suspicious breast lesions: results of a freehand technique.

van den Bosch M, Daniel B, Pal S, Nowels K, Birdwell R, Jeffrey S Eur Radiol. 2006; 16(8):1811-7.

PMID: 16683117 DOI: 10.1007/s00330-006-0214-5.